-
- Awni M Al-Subu, Vu T Nguyen, Yousef AlAli, Rhonda A Yngsdal-Krenz, Michael R Lasarev, Marlowe W Eldridge, and Scott A Hagen.
- Division of Pediatric Critical Care Medicine, Department of Pediatrics, American Family Children's Hospital, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin. al-subu@pediatrics.wisc.edu.
- Respir Care. 2020 Oct 1; 65 (10): 1464-1469.
BackgroundHigh-flow nasal cannula (HFNC) is commonly used to provide respiratory support to pediatric patients with respiratory failure. Although the use of bronchodilators via HFNC has been described, the feasibility and safety of aerosolized bronchodilator delivery via HFNC are controversial. In this study, we sought to evaluate whether the HFNC system can be used to deliver nebulized bronchodilators at lower gas flow of 2-4 L/min, increase patient comfort, and minimize respiratory therapist (RT) bedside time when compared to traditional interfaces.MethodsA retrospective chart review of all pediatric subjects who were admitted to the pediatric ICU in a tertiary care children's hospital and required nebulized bronchodilators between December 2017 and June 2018.ResultsA total of 205 nebulizations were administered to 28 children; 31% of nebulized bronchodilators were given using a nebulization system integrated into the HFNC. Nebulized treatments resulted in an average increase in heart rate of 9.98 (95% CI 3.72-16.2) beats/min when HFNC was used and 0.64 (95% CI -1.65 to 2.93) beats/min when traditional interfaces were used, a difference of 9.34 (95% CI 2.30-16.4) beats/min (P < .001). RT bedside time was significantly longer for HFNC nebulized treatments (P = .031). Subjective level of comfort was not statically different when nebulized bronchodilators were delivered via HFNC or via traditional interfaces. Length of pediatric ICU stay was not statistically different between subjects who received some aerosol nebulized bronchodilators via HFNC versus those who received all bronchodilators through traditional interfaces (P = .11).ConclusionsAerosol bronchodilator delivery using HFNC is feasible at low gas flow (ie, 2-4 L/min). However, the use of HFNC did not improve subjects' comfort, and it increased RT bedside time. Further prospective randomized studies are needed to determine the efficacy and efficiency of aerosol therapy delivered through HFNC and potential patient-oriented outcomes.Copyright © 2020 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.