    Reliability of smartphone measurements of vital parameters: A prospective study using a reference method.

    • İsmail Tayfur and Mustafa Ahmet Afacan.
    • University of Health Sciences, Haydarpaşa Numune Training and Research Hospital, Department of Emergency Medicine, Tıbbiye Street, Üsküdar, İstanbul, Turkey. Electronic address: ismail.tayfur@sbu.edu.tr.
    • Am J Emerg Med. 2019 Aug 1; 37 (8): 1527-1530.

    ObjectiveIn this study, we aimed to evaluate the accuracy of HR and SaO2 data obtained using a smartphone compared with the measurements of a vital signs monitor (VSM) and an arterial blood gas (ABG) device, respectively.Material And MethodsIn this single-center prospective study, the HR and SaO2 measurements were performed using the built-in sensor and light source of a Samsung Galaxy S8 smartphone and compared to the results of VSM and ABG device. The Bland-Altman analysis was used to evaluate and visualize the agreement between the methods.ResultsThe data of 101 patients were analyzed. There was a high correlation between HR measured by smartphone and HR measured by VSM [P < 0.0001; 0.9918 (95% CI = 0.987-0.994)]. In addition, the SaO2 values obtained by smartphone were highly correlated with those by ABG (P < 0.0001; 0.968 (95% CI = 0.952-0.978)).ConclusionThe HR and SaO2 values obtained by smartphone were found to be consistent with the measurements of the reference devices. With the growing use of smartphone technology in the health field, we foresee that patients will be able to make their own triage assessment before presenting to the hospital.Copyright © 2019 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…