Comparative Study
Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression.
- Tyler Marshall, Amit Momaya, Alan Eberhardt, Nilesh Chaudhari, and Thomas R Hunt.
- Division of Orthopedic Surgery, University of Alabama at Birmingham, Birmingham, AL.
- J Hand Surg Am. 2015 Oct 1; 40 (10): 2032-8.
PurposeTo determine biomechanical differences between a fixed-angle locking volar titanium plate (VariAx; Stryker, Kalamazoo, MI) and a fixed-angle compression locking volar stainless steel plate (CoverLoc Volar Plate; Tornier, Amsterdam, Netherlands) in the fixation of simulated AO C3 distal radius fractures.MethodsEighteen cadaveric upper extremities (9 matched pairs) with an average age of 54 years were tested. A 4-part AO C3 fracture pattern was created in each specimen. The fractures were reduced under direct vision and fixed with either the fixed-angle locking volar titanium plate or the fixed-angle compression locking volar stainless steel plate. Motion tracking analysis was then performed while the specimens underwent cyclic loading. Changes in displacement, rotation, load to failure, and mode of failure were recorded.ResultsThe fragments, when secured with the fixed-angle compression locking stainless steel construct, demonstrated less displacement and rotation than the fragments secured with the fixed-angle locking titanium plate under physiological loading conditions. In the fixed-angle compression locking stainless steel group, aggregate displacement and rotation of fracture fragments were 5 mm and 3° less, respectively, than those for the fixed-angle locking titanium group. The differences between axial loads at mechanical failure and stiffness were not statistically significant. The compression locking stainless steel group showed no trend in mode of failure, and the locking titanium plate group failed most often by articular fixation failure (5 of 9 specimens).ConclusionsThe fixed-angle compression locking stainless steel volar plate may result in less displacement and rotation of fracture fragments in the fixation of AO C3 distal radius fractures than fixation by the fixed-angle locking volar titanium plate. However, there were no differences between the plates in mechanical load to failure and stiffness.Clinical RelevanceFixation of distal radius AO C3 fracture patterns with the fixed-angle compression locking stainless steel plate may provide improved stability of fracture fragments.Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.