    Measurement of knee joint range of motion with a digital goniometer: A reliability study.

    • Melanie Svensson, Veronika Lind, and Marita Löfgren Harringe.
    • Hela Kroppen Fysioterapi och Friskvård AB, Stockholm, Sweden.
    • Physiother Res Int. 2019 Apr 1; 24 (2): e1765.

    ObjectivesMeasurements of joint range of motion (ROM) are part of a physical therapist's daily work. Activities of daily living and exercises can be complicated to perform when ROM is limited, and depending on the demands in daily living, the knee joint requires different ROM. In sports, a few degrees in ROM may make the difference between getting injured or not. The goals for physical therapists are to help the patients to regain full ROM, mobility, strength, and function after sustaining an injury. To measure joints with the manual universal goniometer is considered time-consuming and difficult with respect to repeated measurements. Recently, a new digital instrument for measuring ROM was developed-EasyAngle. A first objective of the study was to investigate the reliability of EA for measuring knee joint angles, considering intrarater and interrater reliability. A second objective was to investigate if there were any differences in the intrarater reliability between a novice and an experienced assessor.MethodPassive knee angles were measured in fixed positions for 40 knee joints (20 subjects). Two registered physical therapists, one novice and one experienced, conducted the measurements. Both registered physical therapists were blinded to the measurements throughout the study.ResultsThe results showed very good intrarater (intraclass correlation coefficient [ICC] 0,997-0,998, standard error of mean 1.15-1.48, smallest detectable difference [SDD] 3.19-4.09, limits of agreement -3.36-3.04, -4.66-4.09) and interrater reliability (ICC 0.994, standard error of mean 2.11, SDD 5.85, limits of agreement -4.75-6.95) for measurements of knee joint ROM. No statistical difference between a novice and an experienced assessor was detected (p = 0.86).ConclusionThe results of the present study showed very good ICC values for both intrarater and interrater reliability measuring knee joint ROM with EasyAngle. Relatively high SDD values were seen for both assessors and may indicate a problem monitoring small differences between measurements. Further studies are recommended to increase the generalizability of the results.Copyright © 2018 John Wiley & Sons, Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…