Anesthesia and analgesia · Apr 2020
Multicenter Study Observational StudyMulticenter Evaluation of the Quantra QPlus System in Adult Patients Undergoing Major Surgical Procedures.
- Danja S Groves, Ian J Welsby, Bhiken I Naik, Kenichi Tanaka, Jennifer N Hauck, Charles S Greenberg, Deborah A Winegar, and Francesco Viola.
- From the Department of Anesthesiology, University of Virginia, Charlottesville, Virginia.
- Anesth. Analg. 2020 Apr 1; 130 (4): 899-909.
BackgroundThe management of perioperative bleeding and the optimization of the available therapies are subjects of significant clinical interest. Clinical guidelines recommend the use of whole blood viscoelastic testing devices to target the utilization of blood products during major surgical procedures. The Quantra QPlus System is a new cartridge-based viscoelastic testing device based on an innovative ultrasound technology. The aim of this study was to evaluate this new system in a surgical population.MethodsTwo hundred seventy-seven adult subjects were enrolled in a multicenter, prospective observational study consisting primarily of patients undergoing cardiac and major orthopedic surgeries. Samples were obtained at multiple time points for testing on the Quantra QPlus System, the rotational thromboelastometry (ROTEM) delta, and standard coagulation tests. Quantra measurements included Clot Time (CT), Heparinase Clot Time (CTH), Clot Time Ratio (CTR), Clot Stiffness (CS), Fibrinogen (FCS), and Platelet (PCS) Contributions to CS. Data analyses included assessment of the concordance of Quantra parameters with a series of clinical composite indexes formed on the basis of standard coagulation tests in 3 domains representing increased, decreased, and normal/subclinical coagulation function. Linear regression and receiver operator characteristic (ROC) analyses of Quantra parameters with corresponding parameters from ROTEM assays were also performed.ResultsThe accuracy (overall percent agreement or ratio of true positives and true negatives over the entire population) between the Quantra and the composite indexes was between 72% and 98% depending on the specific parameter. Linear regression analysis indicated that the correlation between ROTEM delta and Quantra was very strong with r values ranging between 0.84 and 0.89. Results from ROC analysis demonstrated sensitivities and specificities in the 80%-90% range when QPlus parameters were used to discriminate ROTEM threshold values currently used in goal-directed treatment algorithms.ConclusionsThis study demonstrated that the Quantra QPlus System is strongly correlated with a well-established viscoelastic testing device and its parameters effectively represent the results from multiple standard laboratory assays. The Quantra has been designed to operate at the point of care with the potential to provide rapid and comprehensive results to aid in the management of coagulopathic patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.