BackgroundBalloon atrial septostomy is performed in infants with dextro-transposition of the great arteries to improve oxygenation before surgery. It is performed in the catheterisation laboratory with fluoroscopy or at the bedside using echocardiography. It is unclear whether procedural safety and efficacy is superior in one location versus the other, although the bedside procedure may improve resource utilisation and present an opportunity for reducing cost. This study compares safety and efficacy of atrial septostomy performed at the patient's bedside versus the catheterisation laboratory.MethodsNeonates with dextro-transposition of the great arteries who underwent balloon atrial septostomy from October, 2000 to January, 2014 were included. Medical and procedural records, echocardiograms, and catheterisation data were reviewed. Comparisons between the two procedural locations included patient demographics, pre- and post-procedure oxygen saturations, and outcomes. Complications reviewed included bleeding, arrhythmia, cardiac trauma, stroke, and death. Coronary artery evaluations were recorded. T-tests were used for continuous variables, and Fisher's exact tests were used for all categorical variables. Wilcoxon rank sum and analysis of covariance modelling were used for time variables and oxygen saturation, respectively.ResultsA total of 88 infants met the inclusion criteria. Among them, 53 underwent septostomy at the bedside and 35 underwent septostomy in the catheterisation laboratory. No safety or outcome benefit was identified between the two procedural locations.ConclusionSeptostomy performed at the bedside and in the catheterisation laboratory had similar outcomes and efficacy. Further, bedside septostomy has the advantage of no radiation exposure, and obviating risks with patient transfer from the ICU to the catheterisation laboratory.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.