• World J Pediatr Congenit Heart Surg · Jul 2014

    Impact of Pulsatile Flow Settings on Hemodynamic Energy Levels Using the Novel Diagonal Medos DP3 Pump in a Simulated Pediatric Extracorporeal Life Support System.

    • Pelumi Adedayo, Shigang Wang, Allen R Kunselman, and Akif Ündar.
    • Department of Pediatrics, Penn State Hershey Pediatric Cardiovascular Research Center, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, PA, USA.
    • World J Pediatr Congenit Heart Surg. 2014 Jul 1; 5 (3): 440-8.

    BackgroundThe objective of this study was to evaluate the pump performance of the novel diagonal Medos Deltastream DP3 diagonal pump (MEDOS Medizintechnik AG, , Stolberg, Germany) under nonpulsatile to pulsatile mode with varying differential speed values in a simulated pediatric extracorporeal life support system.MethodsThe experimental circuit consisted of a Medos Deltastream DP3 pump head and console, a Medos Hilite 2400 LT hollow fiber membrane oxygenator (MEDOS Medizintechnik AG), a 14F Medtronic DLP arterial cannula (Medtronic Inc, Minnesota), and a 20F Terumo TenderFlow Pediatric venous return cannula (Terumo Corporation, Michigan). Trials were conducted at flow rates ranging from 500 mL/min to 2,000 mL/min (500 mL/min increments) and pulsatile differential speed values ranging from 500 rpm to 2,500 rpm (500 rpm increments) using human blood (hematocrit 35%). The postcannula pressure was maintained constantly at 60 mm Hg. Real-time pressure and flow data were recorded using a custom-made data acquisition system and Labview software.ResultsUnder all experimental conditions, pulsatile flow (P) generated significantly greater energy equivalent pressure (EEP), surplus hemodynamic energy (SHE), and total hemodynamic energy (THE) than those of nonpulsatile flow (NP). Under NP, SHE was zero. Higher differential speed values generated greater EEP, SHE, and THE values. There was little variation in the oxygenator pressure drop and the cannula pressure drop in P, compared to NP.ConclusionsThe novel Medos Deltastream DP3 diagonal pump is able to generate physiological quality of P, without backflow. With increased differential rpm, the pump generated greater EEP, SHE, and THE. Physiological quality of pulsatility may be associated with better microcirculation because of greater EEP, SHE, and THE.© The Author(s) 2014.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.