    Comparison of three methods for beat-to-beat-interval extraction from continuous blood pressure and electrocardiogram with respect to heart rate variability analysis.

    • Alexander Suhrbier, Rafael Heringer, Thomas Walther, Hagen Malberg, and Niels Wessel.
    • Institute for Computer Science, Humboldt University Berlin, Germany.
    • Biomed Tech (Berl). 2006 Jul 1; 51 (2): 70-6.

    AbstractIn recent years the analysis of heart rate variability (HRV) has become a suitable method for characterizing autonomous cardiovascular regulation. The aim of this study was to investigate the differences in HRV estimated from continuous blood pressure (BP) measurement by different methods in comparison to electrocardiogram (ECG) signals. The beat-to-beat intervals (BBI) were simultaneously extracted from the ECG and blood pressure of 9 cardiac patients (10 min, Colin system, 1000-Hz sampling frequency). For both data types, slope, peak, and correlation detection algorithms were applied. The short-term variability was calculated using concurrent 10-min BP and ECG segments. The root mean square errors in comparison to ECG slope detection were: 1.74 ms for ECG correlation detection; 5.42 ms for ECG peak detection; 5.45 ms for BP slope detection; 5.75 ms for BP correlation detection; and 11.96 ms for BP peak detection. Our results show that the variability obtained with ECG is the most reliable. Moreover, slope detection is superior to peak detection and slightly superior to correlation detection. In particular, for ECG signals with higher frequency characteristics, peak detection often exhibits more artificial variability. Besides measurement noise, respiratory modulation and pulse transit time play an important role in determining BBI. The slope detection method applied to ECG should be preferred, because it is more robust as regards morphological changes in the signals, as well as physiological properties. As the ECG is not recorded in most animal studies, distal pulse wave measurement in combination with correlation or slope detection may be considered an acceptable alternative.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.