• Ann Card Anaesth · Apr 2016

    Randomized Controlled Trial

    A randomized trial to assess the utility of preintubation adult fiberoptic bronchoscope assessment in patients for thoracic surgery requiring one-lung ventilation.

    • Nayana Amin, Pritee Tarwade, Madhavi Shetmahajan, C S Pramesh, Sabita Jiwnani, Abhishek Mahajan, and Nilendu Purandare.
    • Department of Anesthesiology, Tata Memorial Centre, Mumbai, Maharashtra, India.
    • Ann Card Anaesth. 2016 Apr 1; 19 (2): 251-5.

    BackgroundConfirmation of placement of Double lumen endobronchial tubes (DLETT) and bronchial blockers (BBs) with the pediatric fiberoptic bronchoscope (FOB) is the most preferred practice worldwide. Most centers possess standard adult FOBs, some, particularly in developing countries might not have access to the pediatric-sized devices. We have evaluated the role of preintubation airway assessment using the former, measuring the distance from the incisors to the carina and from carina to the left and right upper lobe bronchus in deciding the depth of insertion of the lung isolation device.MethodsThe study was a randomized, controlled, double-blind trial consisting of 84 patients (all >18 years) undergoing thoracic surgery over a 12-month period. In the study group (n = 38), measurements obtained during FOB with the adult bronchoscope decided the depth of insertion of the lung isolation device. In the control group (n = 46), DLETTs and BBs were placed blindly followed by clinical confirmation by auscultation. Selection of the type and size of the lung isolation device was at the discretion of the anesthesiologist conducting the case. In all cases, pediatric FOB was used to confirm accurate placement of devices.ResultsOf 84 patients (DLETT used in 76 patients; BB used in 8 patients), preintubation airway measurements significantly improved the success rate of optimal placement of lung isolation device from 25% (11/44) to 50% (18/36) (P = 0.04). Our incidence of failed device placement at initial insertion was 4.7% (4/84). Incidence of malposition was 10% (8/80) with 4 cases in each group. The incidence of suboptimal placement was lower in the study group at 38.9% (14/36) versus 65.9% (29/44).ConclusionsPreintubation airway measurements with the adult FOB reduces airway manipulations and improves the success rate of optimal placement of DLETT and BB.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…