• The Journal of pediatrics · Jun 2006

    Randomized Controlled Trial Comparative Study

    Neonatal laryngoscope intubation and the digital method: a randomized controlled trial.

    • José Henrique Silva Moura and da Silva Gisélia Alves Pontes GA.
    • Department of Neonatology, Hospital de Avila, Recife, Brazil. jhmoura@elogica.com.br
    • J. Pediatr. 2006 Jun 1; 148 (6): 840-1.

    AbstractWe compared digital intubation (DI) and laryngoscope intubation (LI) in newborns. The success rate was 90.5% for DI and 50% for LI (P = .004). It took 8.2 seconds to complete the DI and 13.1 seconds to complete the LI (P = .007). DI should be considered to be an option for neonatal intubation.

      Pubmed     Full text   Copy Citation     Plaintext  