- Da Zou, Zhuoran Sun, Siyu Zhou, Woquan Zhong, and Weishi Li.
- Orthopaedic Department, Peking University Third Hospital, No. 49 North Garden Road, Haidian District, Beijing, 100191, China.
- Eur Spine J. 2020 May 1; 29 (5): 1105-1111.
PurposeTo compare the performance of using Hounsfield units (HU) value derived from computed tomography and T-score of dual-energy X-ray absorptiometry (DXA) to predict pedicle screw loosening.MethodsWe reviewed 253 patients aged ≥ 50 years undergoing pedicle screw fixation for lumbar degenerative diseases (LDD). The evaluation of screw loosening: radiolucent zones of ≥ 1 mm thick in X-ray. The criterion for osteoporosis: the lowest T-score ≤ - 2.5. The average HU value of L1-L4 was used to represent lumbar bone mineral density (BMD). The area under receiver operating characteristics curve (AUC) was used to evaluate the performance of predicting screw loosening.ResultsOne patient underwent reoperation for screw loosening at 9 months follow-up. At 12 months follow-up, the loosening rate was 30.6% (77/252) in the remaining 252 patients. Osteoporotic patients had higher loosening rate than non-osteoporotic patients (39.3% vs. 25.8%, P = 0.026). The T-score showed no significant difference between loosening group and non-loosening group (- 2.1 ± 1.5 vs. - 1.7 ± 1.6, P = 0.074), and so is the lowest lumbar BMD of DXA (0.83 ± 0.16 g/cm2 vs. 0.88 ± 0.19 g/cm2, P = 0.054). The HU value was lower in the loosening group (106.8 ± 34.4 vs. 129.8 ± 45.7, P < 0.001). The HU value (OR, 0.980; 95%CI 0.968-0.993; P = 0.002) was the independent influencing factor of screw loosening. The AUC of predicting screw loosening was 0.666 (P < 0.001) for HU value and 0.574 (P = 0.062) for T-score.ConclusionsHU value is a better predictor of pedicle screw loosening than T-score of DXA in patients aged ≥ 50 years with LDD. We should not only focus on the DXA measurements when making surgical plans concerning lumbar fixation. These slides can be retrieved under Electronic Supplementary Material.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.