• J Ultrasound Med · Mar 2020

    Tracheal Ultrasound for the Accurate Confirmation of the Endotracheal Tube Position in Obese Patients.

    • Xiao Qian Men and Xi Xin Yan.
    • Department of Respiratory and Critical Care Medicine, Second Hospital of Hebei Medical University, Shijiazhuang, China.
    • J Ultrasound Med. 2020 Mar 1; 39 (3): 509-513.

    ObjectivesObesity is a serious disorder that may lead to numerous difficulties in endotracheal tube (ETT) management. This study investigated the potential of tracheal ultrasound (TUS) for the accurate confirmation of the ETT position in obese patients.MethodsA total of 68 obese patients undergoing tracheal intubation were enrolled in this study from January 2017 to June 2018. All patients received auscultation and TUS to evaluate the ETT position, which was ultimately verified by bronchoscopy. A correct position of the ETT was defined as placement at the trachea, whereas placement at the right/left main bronchus was classified as an incorrect position.ResultsWe found 58 correct placements of the ETT at the trachea, 8 incorrect placements at the right main bronchus, and 2 incorrect placements at the left main bronchus. Compared with auscultation, TUS showed higher accuracy (85.29% versus 67.65%; P = .005), sensitivity (84.48% versus 67.24%; P = .005), and specificity (90.00% versus 70.00%; P < .001), as well as lower rates of false-positive (10.00% versus 30.00%; P < .001) and false-negative (15.52% versus 32.76%; P = .005) results for detecting the correct placement of the ETT, defined as placement at the trachea.ConclusionsTracheal ultrasound is highly sensitive and specific in confirming the ETT position in obese patients.© 2019 by the American Institute of Ultrasound in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.