- Joost Lc Lokin, Soray Dulger, Gerie J Glas, and Janneke Horn.
- Department of Cardiovascular Surgery, Amsterdam UMC, Amsterdam, the Netherlands. j.l.lokin@amsterdamumc.nl.
- Respir Care. 2020 Sep 1; 65 (9): 1309-1314.
BackgroundDetection of diaphragmatic muscle activity during invasive ventilation may provide valuable information about patient-ventilator interactions. Transesophageal electromyography of the diaphragm ([Formula: see text]) is used in neurally adjusted ventilatory assist. This technique is invasive and can only be applied with one specific ventilator. Surface electromyography of the diaphragm ([Formula: see text]) is noninvasive and can potentially be applied with all types of ventilators. The primary objective of our study was to compare the ability of diaphragm activity detection between [Formula: see text] and [Formula: see text].MethodsIn this single-center pilot study, [Formula: see text] and [Formula: see text] recordings were obtained simultaneously for 15 min in adult subjects in the ICU who were invasively ventilated. The number of breathing efforts detected by [Formula: see text] and [Formula: see text] were determined. The percentage of detected breathing efforts by [Formula: see text] compared with [Formula: see text] was calculated. Temporal and signal strength relations on optimum recordings of 10 breaths per subject were also compared. The Spearman correlation coefficient was used to determine the correlation between [Formula: see text] and [Formula: see text]. Agreement was calculated by using Bland-Altman statistics.ResultsFifteen subjects were included. The [Formula: see text] detected 3,675 breathing efforts, of which 3,162 (86.0%) were also detected by [Formula: see text]. A statistically significant temporal correlation (r = 0.95, P < .001) was found between [Formula: see text] and [Formula: see text] in stable recordings. The mean difference in the time intervals between both techniques was 10.1 ms, with limits of agreement from -410 to 430 ms.ConclusionsAnalysis of our results showed that [Formula: see text] was not reliable for breathing effort detection in subjects who were invasively ventilated compared with [Formula: see text]. In stable recordings, however, [Formula: see text] and [Formula: see text] had excellent temporal correlation and good agreement. With optimization of signal stability, [Formula: see text] may become a useful monitoring tool.Copyright © 2020 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.