-
- Aaron B Holley, Donovan L Mabe, John C Hunninghake, Jacob F Collen, Robert J Walter, John H Sherner, Nikhil A Huprikar, and Michael J Morris.
- Department of Pulmonary/Sleep and Critical Care Medicine, Walter Reed National Military Medical Center, Bethesda, Maryland. aholley9@gmail.com.
- Respir Care. 2020 Oct 1; 65 (10): 1488-1495.
BackgroundThe effect of isolated small airway dysfunction (SAD) on exercise remains incompletely characterized. We sought to quantify the relationship between isolated SAD, identified with lung testing, and the respiratory response to exercise.MethodsWe conducted a prospective evaluation of service members with new-onset dyspnea. All subjects underwent plethysmography, diffusing capacity of the lung for carbon monoxide (DLCO), impulse oscillometry, high-resolution computed tomography (HRCT), and cardiopulmonary exercise testing (CPET). In subjects with normal basic spirometry, DLCO, and HRCT, SAD measures were analyzed for associations with ventilatory parameters at submaximal exercise and at maximal exercise during CPET.ResultsWe enrolled 121 subjects with normal basic spirometry (ie, FEV1, FVC, and FEV1/FVC), DLCO, and HRCT. Mean age and body mass index were 37.4 ± 8.8 y and 28.4 ± 3.8 kg/m2, respectively, and 110 (90.9%) subjects were male. The prevalence of SAD varied from 2.5% to 28.8% depending on whether FEV3/FVC, FEF25-75%, residual volume/total lung capacity, and R5-R20 were used to identify SAD. Agreement on abnormal SAD across tests was poor (kappa = -0.03 to 0.07). R5-R20 abnormalities were related to higher minute ventilation ([Formula: see text]) and higher [Formula: see text]/maximum voluntary ventilation (MVV) during submaximal exercise and to lower [Formula: see text] during maximal exercise. After adjustment for differences at baseline, there remained a trend toward a relationship between R5-R20 and an elevated [Formula: see text]/MVV during submaximal exercise (β = 0.04, 95% CI -0.01 to 0.09, P = .10), but there was no significant association with [Formula: see text] during submaximal exercise or with [Formula: see text] during maximal exercise. No other SAD measures showed a relationship with ventilatory parameters.ConclusionsIn 121 subjects with normal basic spirometry, DLCO, and HRCT, we found poor agreement across tests used to detect SAD. Among young, healthy service members with postdeployment dyspnea, SAD as identified by lung function testing does not predict changes in the ventilatory response to exercise.Copyright © 2020 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.