• Indian J Orthop · Mar 2016

    Autoclaved metal-on-cement spacer versus static spacer in two-stage revision in periprosthetic knee infection.

    • Yu-Pin Chen, Cheng-Chun Wu, and Wei-Pin Ho.
    • Department of Orthopaedic Surgery, Wan Fang Hospital, School of Medicine, Taipei Medial University, Taipei, Taiwan, ROC.
    • Indian J Orthop. 2016 Mar 1; 50 (2): 146-53.

    BackgroundPeriprosthetic knee infection is troublesome for Orthopedic surgeons and a catastrophy for patients. Reported rates of periprosthetic joint infection following primary total knee arthroplasty (TKA) are 0.39-2%. Two stage revision arthroplasty, which has success rates exceeding 90%, has been the gold standard for treating subacute and chronic periprosthetic infection following TKA. Antibiotic spacers, a well established means of delivering local antibiotic therapy, maintain soft tissue tension during two stage revision arthroplasty. However, controversy remains around whether static or mobile antibiotic impregnated spacers are superior for treating infection following TKA. Various mobile spacers are available, including cement-on-cement, cement-on-polyethylene and metal-on-polyethylene. In this study, the efficacy of the modified metal-on-cement spacer, consisting of reinsertion of the autoclaved femoral component and implantation of antibiotic-loaded cement in the proximal tibia, is assessed.Materials And MethodsRecords of 19 patients diagnosed as periprosthetic knee infection were reviewed in this retrospective study. Among these patients, 10 patients received first stage debridement with the autoclaved metal-on-cement spacer and 8 patients with the static spacer, who eventually underwent two-stage re-implantation, were listed in the final comparison. Patient demographics, infection eradication rates, average range of motion (ROM), surgical time and blood loss during the second-stage of the surgery, and Knee Society (KS) knee scores at last followup after revision total knee replacement were clinically evaluated.ResultsAt a minimum of 2-year followup after re-implantation, infection eradication rates, surgical times, blood loss during the second-stage of the surgery, and KS knee score after re-implantation were similar for the two groups. Patients receiving autoclaved metal-on-cement spacers had superior ROM after re-implantation compared to that of patients with static spacers.ConclusionsThe autoclaved metal-on-cement spacer is an effective and simple method for two-stage re-implantation of a periprosthetic knee infection. Through this spacer, the good interim ROM can be achieved without the additional cost of prefabricated molds or new polyethylene tibial inserts. In addition, ROM after re-implantation is better than that with static spacers.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.