-
Journal of anesthesia · Aug 2020
Observational StudyFeasibility, safety, and economic consequences of using low flow anesthesia according to body weight.
- Yusuf Z Colak and Hüseyin I Toprak.
- Department of Anesthesiology, Medical Faculty, İnönü University, 44280, Malatya, Turkey. yzcolak@gmail.com.
- J Anesth. 2020 Aug 1; 34 (4): 537-542.
BackgroundLow flow anesthesia (LFA) provides a saving up to 75% and improves the dynamics of inhaled anesthesia gas, increases mucociliary clearance, maintains body temperature, and reduces water loss. LFA has been recommended for anesthesiologists in recent years to avoid high fresh gas flow (FGF). However, LFA use is limited due to associated risks. The main purpose of this study was to investigate whether LFA according to body weight, which is the main determinant of oxygen requirement, is feasible and safe in the normoxia range. The second aim was to show that this method can provide economic benefit.MethodsEighty donor hepatectomy cases were included to study in two groups as prospective, observational. A surgery room and a team were allocated only for this study. Considering the oxygen requirement (approximately 3-3.5 mL/kg/min), for the first 40 cases, 10 mL/kg (group 10) FGF was applied; for the second 40 cases, 20 mL/kg (group 20) was applied. Desflurane (Suprane©) was used as an inhalation agent, and analgesia was achieved with remifentanil infusion. Patients' demographic, respiratory, hemodynamic, and tissue perfusion parameters (SpO2 and NIRS), and comsumption data (anesthetic agent and CO2 absorbent) were collected and compared.ResultsNo significant differences were detected between the groups in terms of demographic data, duration of surgery, and hemodynamic, respiratory, and tissue perfusion parameters. These parameters were within normal limits in all patients at all times. The maximum O2 concentration in the FGF that maintained FiO2:0.4 and provided adequate oxygenation during the LFA was 61% (min 56%; max 67%) in group 10, and 47% (min 43%; max 51%) in group 20. The hourly anesthetic agent consumption was significantly different in group 10 than in group 20 (12.4 ± 4 mL vs. 21.5 ± 8 mL/h, respectively (p < 0.001).ConclusionsWe performed 10 mL/kg FGF speed without deviating from the safety limits to be FiO2:0.4 in donor hepatectomies, reducing the total costs 38% compared with 20 mL/kg FGF.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.