• J Ultrasound Med · Apr 2020

    Observational Study

    Carotid Artery Corrected Flow Time and Respiratory Variations of Peak Blood Flow Velocity for Prediction of Hypotension After Induction of General Anesthesia in Adult Patients Undergoing Elective Surgery: A Prospective Observational Study.

    • Souvik Maitra, Dalim K Baidya, Rahul K Anand, Rajeshwari Subramanium, and Sulagna Bhattacharjee.
    • Department of Anesthesiology, Pain Medicine, and Critical Care, All India Institute of Medical Sciences, New Delhi, India.
    • J Ultrasound Med. 2020 Apr 1; 39 (4): 721-730.

    ObjectivesHypotension is common after induction of general anesthesia, and intraoperative hypotension is associated with postoperative end-organ injury such as acute kidney injury and myocardial ischemia. This study was designed to determine the utility of the carotid corrected flow time (cFT) and carotid artery peak blood flow velocity variation (ðVpeak ) for prediction of hypotension after induction of general anesthesia.MethodsAdult patients (n = 112) undergoing any elective surgery under general anesthesia who fasted for at least 6 to 8 hours were recruited in this prospective observational study. The common carotid artery cFT and ðVpeak were measured with ultrasound 10 minutes before induction of general anesthesia. After that, general anesthesia with propofol was used, and hemodynamic data were collected until 3 minutes after induction of anesthesia.ResultsThe carotid cFT was significantly correlated with percentages of the fall in the systolic blood pressure at 2 minutes (P < .0001) and 3 minutes (P < .0001) and percentages of the fall in the mean arterial pressure at 1 minute (P = .0006), 2 minutes (P < .0001), and 3 minutes (P < .0001). The cFT was a predictor of hypotension after induction of general anesthesia, with an area under the receiver operating characteristic curve of 0.91. The best cutoff value obtained from this study was 330.2 milliseconds or less, which predicted postinduction hypotension with sensitivity and specificity of 85.7% and 96.8%, respectively. The ðVpeak was an inferior predictor of postinduction hypotension, with an area under the receiver operating characteristic curve of 0.68. The optimum cutoff value was 18.8%, with sensitivity and specificity of 61.9% and 67.4%.ConclusionsThe cFT measured in the common carotid artery is a reasonable predictor of hypotension after induction of general anesthesia in American Society of Anesthesiologists physical status I and II patients. Further studies are required to identify its role in high-risk patients such as older groups and patients with cardiovascular diseases and also to identify interobserver and intraobserver variability of cFT and ðVpeak measurements.© 2019 by the American Institute of Ultrasound in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…