• Int J Crit Illn Inj Sci · Oct 2019

    Clinical evaluation of Ambu® Aura-i™ - A new intubating laryngeal mask airway as an independent ventilatory device and a conduit for tracheal intubation in pediatric patients.

    • Triveni M Rangaswamy, Avnish Bharadwaj, and Priyanka Jain.
    • Department of Anaesthesiology, Bangalore Medical College and Research Institute, Bengaluru, Karnataka, India.
    • Int J Crit Illn Inj Sci. 2019 Oct 1; 9 (4): 157-163.

    BackgroundAmbu® Aura-i™, a recently introduced second generation supraglottic airway device has been designed to function as an independent ventilatory device as well as a conduit for passage of conventional cuffed tracheal tubes through it. There is dearth of literature on experience of tracheal intubation through intubating laryngeal mask airway (ILMA) in paediatric age group. This study was conducted to study the ventilatory effectiveness and the intubating characteristics of Ambu® Aura-i™ in paediatric patients.AimTo study the effectiveness of Ambu ® Aura-i ™ as a supraglottic device for its ventilatory effectiveness and intubation characteristics in paediatric patients.ObjectivesTo study the Ventilatory effectiveness of Ambu ® Aura-i ™ in terms of: 1) Time taken in insertion of Ambu ® Aura-i ™. 2) No of attempts made for successful insertion of Ambu ® Aura-i™. 3) Tidal volume attained on positive pressure ventilation. 4) Etco2, Spo2 and Leak pressure achieved. To study the Intubating characterstics of Ambu ® Aura-i ™ in terms of :- 1) Grade of alignment of the ventilating orifice achieved in relation to the larynx in the fibre optic view. 2) Time taken in intubation through Ambu ® Aura-i ™. 3) Number of attempts made in intubation. 4) Time taken for removal of the Ambu ® Aura-i ™ after intubation through it has been accomplished.MethodSixty three children undergoing elective surgery under general anaesthesia requiring intubation of trachea, weighing between 5-30 kg were stratified into 3 groups (n= 21) each. Ambu® Aura-i™ size 1.5 , 2.0 ,2.5 were used based on their body weight for airway management. Ventilatory effectiveness was studied in terms of success rate, number of attempts made at insertion, time taken in insertion, tidal volume delivered and leak pressure achieved. Intubating characterstics studied during fibreoptic guided tracheal intubation included grade of alignment of the ventilating orifice achieved in relation to the larynx in fibre optic view, time taken in fibreoptic guided tracheal intubation, success rate and number of attempts made at intubation. Time taken in removal of the device and complications observed were also recorded.ResultsAmbu® Aura-i™ insertion, fibreoptic guided tracheal intubation and device removal were successful in all the patients in first attempt. The mean time taken in successful device insertion was 10.83±2.04 sec. The mean tidal volume delivered was 7.88±1.33 ml/kg body weight and mean leak pressure achieved was 16.27±5.2 cm H2O. The fibreoptic guided intubation was possible in first attempt in 100% of the patients (n=63). The Fibre optic view was grade 1 in 82.55% patients (n=52 /63) and grade 2 in 17.46% (n=11/ 63) patients. The mean time taken in fibre optic guided intubation was 12.68 ±2.82 sec. The mean time taken in removal of the device over the tracheal tube was 12.27 sec. There was no significant incidence of trauma to soft tissues, sore throat, laryngospasm or hoarseness of voice.ConclusionOn the basis of observations of this study, we conclude that Ambu ® Aura-i ™ is not only an effective ventilatoy device, but also an excellent conduit for fibre optic guided intubation using conventional uncuffed endotracheal tube in paediatric patients. Ambu ® Aura-i ™ , is also valuable for establishing rapid airway access in emergent difficult paediatric airway.Copyright: © 2019 International Journal of Critical Illness and Injury Science.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.