• Eur J Anaesthesiol · Aug 2020

    Role of TFA-1 adhesive forehead sensors in predicting fluid responsiveness in anaesthetised children: A prospective cohort study.

    • Eun-Hee Kim, Hansol Kim, Ji-Hyun Lee, Jin-Tae Kim, Young-Eun Jang, Sang-Hwan Ji, and Hee-Soo Kim.
    • From the Department of Anaesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, South Korea (EHK, HK, JHL, JTK, YEJ, SHJ, HSK).
    • Eur J Anaesthesiol. 2020 Aug 1; 37 (8): 713-718.

    BackgroundThe TFA-1 adhesive forehead sensor is a newly developed pulse oximeter for the measurement of the plethysmographic variability index (PVI) at the forehead, and for the rapid detection of changes in oxygen saturation during low perfusion.ObjectivesWe evaluated the ability of the TFA-1 sensor to predict fluid responsiveness in children under general anaesthesia.DesignProspective cohort study.SettingSingle tertiary care children's hospital.PatientsThirty-seven children aged 1 to 5 years under general anaesthesia and requiring invasive arterial pressure monitoring.Main Outcome MeasuresThe baseline PVI of TFA-1 and finger sensors, respiratory variation of aorta blood flow peak velocity (ΔVpeak) and stroke volume index (SVI) obtained using transthoracic echocardiography were assessed. After fluid loading of 10 ml kg crystalloids over 10 min, SVI was reassessed. Responders were defined as those with an increase in SVI greater than 15% from the baseline. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the predictive ability of the PVI of TFA-1 and finger sensors and ΔVpeak for fluid responsiveness.ResultsSeventeen (56.6%) patients responded to volume expansion. Before fluid loading, the PVI of TFA-1 and finger sensors and ΔVpeak (mean ± SD) of the responders were 11.2 ± 4.4, 11.4 ± 5.1 and 14.8 ± 3.9%, respectively, and those of the nonresponders were 7.4 ± 3.9, 8.1 ± 3.6 and 11.0 ± 3.3%, respectively. ROC curve analysis indicated that the PVI of TFA-1 and finger sensors and ΔVpeak could predict fluid responsiveness. The areas under the curve were 0.8 [P = 0.00; 95% confidence interval (CI) 0.60 to 0.91], 0.7 (P = 0.02; 95% CI 0.53 to 0.87) and 0.8 (P = 0.00; 95% CI 0.59 to 0.91), respectively. The cut-off values for the PVI of TFA-1 and finger sensors and ΔVpeak were 6.0, 9.0 and 10.6%, respectively.ConclusionThe PVI of TFA-1 forehead sensor is a good alternative, but is not superior to the finger sensor and ΔVpeak in evaluating fluid responsiveness in mechanically ventilated children under general anaesthesia.Clinical Trial Registrationwww.clinicaltrials.gov, NCT03132480.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…