• Critical care medicine · May 1993

    Functional responses to extremely high plasma epinephrine concentrations in cardiac arrest.

    • J Wortsman, N A Paradis, G B Martin, E P Rivers, M G Goetting, R M Nowak, and P E Cryer.
    • Department of Medicine, Southern Illinois University School of Medicine, Springfield 62794-9230.
    • Crit. Care Med. 1993 May 1; 21 (5): 692-7.

    ObjectiveTo evaluate the action of high-dose epinephrine by measuring simultaneously its vasopressor and norepinephrine releasing effects in humans during cardiac arrest.DesignA prospective study on consecutive patients admitted with cardiac arrest.SettingEmergency Department in a large, urban hospital.PatientsEighteen patients with out-of-hospital cardiac arrest undergoing cardiopulmonary resuscitation (CPR).InterventionsCatheterization of both the aorta and right atrium for the recording of pressure and collection of blood samples. Throughout the study period (12.5 mins), 18 patients received epinephrine at both the standard dose (1 mg, approximately 0.015 mg/kg) and high dose (0.2 mg/kg). Blood samples were drawn five times, every 2.5 mins.Measurements And Main ResultsPlasma epinephrine and norepinephrine concentrations; aorta, right atrial, and coronary perfusion pressures. Epinephrine concentrations (normal at rest = 160 +/- 10 [SEM] pmol/L) were increased at the time of the first sample (2.5 mins) by approximately 3,000-fold (to approximately 0.5 mumol/L), and, increased further to 12,000-fold (approximately 2.0 mumol/L) during the study. Aortic pressure increased from 20 +/- 3 to 28 +/- 3 mm Hg (p < .001), and coronary perfusion pressure increased from 4 +/- 3 to 10 +/- 3 mm Hg (p < .001). Simultaneous plasma norepinephrine concentrations were 30-fold higher than the normal resting value of 1.30 +/- 0.04 nmol/L, and increased by 90-fold during the study (p < .001). The spectral distributions of the individual correlations between plasma epinephrine and norepinephrine concentrations were segregated into high correlations (r > .83) in 12 of 18 patients and low r values (r = .29 to .79) in the remaining six patients. The distribution of the correlations was nonuniform by the Kolmogorov-Smirnov goodness-of-fit test with p < .001; this profile suggests that norepinephrine responsiveness to epinephrine can separate two populations, one of which (r > .83) would have preserved viability of the corresponding epinephrine receptors. The correlations between plasma epinephrine concentrations and coronary perfusion pressures were distributed more evenly, also in a nonuniform pattern (p < .02 by Kolmogorov-Smirnov goodness-of-fit test) and the relationship between the two sets of correlations was not significant.ConclusionsDespite the very high prevailing plasma epinephrine concentrations during cardiac arrest, further epinephrine increases still elicit biological responses. The present work provides physiologic support for the use of large doses of epinephrine during the course of CPR.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…