• J Chin Med Assoc · Jan 2019

    Agreement of post-LASIK corneal power and corneal thickness measurements by pentacam and GALILEI corneal tomography systems.

    • Yun-Hsiu Hsieh, Tzu-Heng Weng, Yu-Ching Chou, Kuan-Liang Wu, Chang-Min Liang, and Ming-Cheng Tai.
    • Department of Ophthalmology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
    • J Chin Med Assoc. 2019 Jan 1; 82 (1): 72-77.

    BackgroundPost-LASIK corneal conditions cannot be accurately measured by traditional optometric approaches. Therefore, we aimed to analyze the agreement of two rotating Scheimpflug cameras in corneal assessment.MethodsFifty otherwise healthy volunteers who had undergone LASIK were recruited in this study. The values of mean and central total corneal power (TCP), including TCP1, TCP2, and TCP-IOL, were measured by GALILEI Scheimpflug camera. The values of total corneal refractive power (TCRP) readings at both 2 mm ring and 3 and 4 mm zones were detected by Pentacam Scheimpflug camera. Central corneal thickness (CCT) and thinnest corneal thickness (TCT) were quantified by GALILEI and Pentacam respectively. Paired t-tests and Bland-Altman analyses were used to evaluate statistical differences between measurement results obtained by GALILEI and by Pentacam.ResultsAmong these 50 subjects, the mean and central TCP1 values (37.31 ± 2.61 and 37.27 ± 2.64) derived from GALILEI measurements were consistent with the TCRP values (37.08 ± 2.76, 37.11 ± 2.74, and 37.19 ± 2.68; p > 0.05) determined by Pentacam at the 2 mm ring apex, 3 mm zone apex, and 4 mm zone apex. There were no statistically significant differences in central corneal thickness (CCT) values measured by the two cameras (463.64 ± 55.67 μm for GALILEI and 470.69 ± 44.04 μm for Pentacam, respectively; p > 0.05). However, the limits of agreement were wide when comparing mean TCP1 (-1.4 to 1.8 D, -1.4 to 1.8 D, and -1.3 to 1.6 D), central TCP1 (-1.2 to 1.6 D, -1.2 to 1.6 D, and -1.2 to 1.4 D) and CCT (-77.2-63.0 μm).ConclusionCorneal power and corneal thickness are disparate post-LASIK evaluation parameters when comparing the utility of GALILEI with that of Pentacam.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.