• PLoS medicine · May 2020

    Randomized Controlled Trial Comparative Study

    Safety and continued use of the levonorgestrel intrauterine system as compared with the copper intrauterine device among women living with HIV in South Africa: A randomized controlled trial.

    • Catherine S Todd, Heidi E Jones, Nontokozo Langwenya, Donald R Hoover, Pai-Lien Chen, Gregory Petro, and Landon Myer.
    • Maternal and Child Health and Nutrition Department, Global Health, Population, and Nutrition, Durham, North Carolina, United States of America.
    • PLoS Med. 2020 May 1; 17 (5): e1003110.

    BackgroundWomen living with HIV (WLHIV) have lower rates of contraceptive use than noninfected peers, yet concerns regarding contraceptive efficacy and interaction with antiretroviral therapy (ART) complicate counseling. Hormonal contraceptives may increase genital tract HIV viral load (gVL) and sexual transmission risk to male partners. We compared gVL, plasma VL (pVL), and intrauterine contraceptive (IUC) continuation between the levonorgestrel intrauterine system (LNG-IUS) and copper intrauterine device (C-IUD) in Cape Town, South Africa.Methods And FindingsIn this double-masked, randomized controlled noninferiority trial, eligible WLHIV were ages 18-40, not pregnant or desiring pregnancy within 30 months, screened and treated (as indicated) for reproductive tract infections (RTIs) within 1 month of enrollment, and virologically suppressed using ART or above treatment threshold at enrollment (non-ART). Between October 2013, and December 2016, we randomized consenting women within ART groups, using 1:1 permuted block randomization stratified by ART use, age (18-23, 24-31, 32-40), and recent injectable progestin contraceptive (IPC) exposure, and provided the allocated IUC. At all visits, participants provided specimens for gVL (primary outcome), pVL, RTI, and pregnancy testing. We assessed gVL and pVL across 6 and 24 months controlling for enrollment measures, ART group, age, and RTI using generalized estimating equation and generalized linear models (non-ART group pVL and hemoglobin) in as-treated analyses. We measured IUC discontinuation rates with Kaplan-Meier estimates and Cox proportional hazards models. We enrolled 71 non-ART (36 LNG-IUS, 31 C-IUD; 2 declined and 2 were ineligible) and 134 ART-using (65 LNG-IUS, 67 C-IUD; 1 declined and 1 could not complete IUC insertion) women. Participant median age was 31 years, and 95% had 1 or more prior pregnancies. Proportions of women with detectable gVL were not significantly different comparing LNG-IUS to C-IUD across 6 (adjusted odds ratio [AOR]: 0.78, 95% confidence interval [CI] 0.44-1.38, p = 0.39) and 24 months (AOR: 1.03, 95% CI: 0.68-1.57, p = 0.88). Among ART users, proportions with detectable pVL were not significantly different at 6 (AOR = 0.83, 95% CI 0.37-1.86, p = 0.65) and 24 months (AOR = 0.94, 95% CI 0.49-1.81, p = 0.85), whereas among non-ART women, mean pVL was not significantly different at 6 months (-0.10 log10 copies/mL, 95% CI -0.29 to 0.10, p = 0.50) between LNG-IUS and C-IUD users. IUC continuation was 78% overall; C-IUD users experienced significantly higher expulsion (8% versus 1%, p = 0.02) and elective discontinuation (adjusted hazard ratio: 8.75, 95% CI 3.08-24.8, p < 0.001) rates. Sensitivity analysis adjusted for differential IUC discontinuation found similar gVL results. There were 39 serious adverse events (SAEs); SAEs believed to be directly related to IUC use (n = 7) comprised 3 pelvic inflammatory disease (PID) cases and 4 pregnancies with IUC in place with no discernible trend by IUC arm. Mean hemoglobin change was significantly higher among LNG-IUS users across 6 (0.57 g/dL, 95% CI 0.24-0.90; p < 0.001) and 24 months (0.71 g/dL, 95% CI 0.47-0.95; p < 0.001). Limitations included not achieving non-ART group sample size following change in ART treatment guidelines and truncated 24 months' outcome data, as 17 women were not yet eligible for their 24-month visit at study closure. Also, a change in VL assay during the study may have caused some discrepancy in VL values because of different limits of detection.ConclusionsIn this study, we found that the LNG-IUS did not increase gVL or pVL and had low levels of contraceptive failure and associated PID compared with the C-IUD among WLHIV. LNG-IUS users were significantly more likely to continue IUC use and had higher hemoglobin levels over time. The LNG-IUS appears to be a safe contraceptive with regard to HIV disease and may be a highly acceptable option for WLHIV.Trial RegistrationClinicalTrials.gov NCT01721798.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.