Clinical physiology and functional imaging
-
Clin Physiol Funct Imaging · Nov 2005
Clinical TrialRecording of dynamic arterial compliance changes during hand elevation.
Finger arterial compliance has been studied on the beat-to-beat basis by using the digital arterial pressure and volume waveforms and performing measurements at zero transmural pressure during arm elevation in 11 volunteers. Continuous non-invasive finger blood pressure was measured by applying the Finapres monitor and the finger volume pulses were recorded by the UT9201 physiograph by using the photoplethysmographic principle of registration. ⋯ The results of the study demonstrate that the applied two methods similarly (correlation coefficient r = 0.97) describe the changes of the beat-to-beat compliance during hand elevation test. At the same time the second estimate was 18% higher than the first one (P = 0.003).