Clinical TrialTemporary shielding of hot spots in the drainage areas of cutaneous melanoma improves accuracy of lymphoscintigraphic sentinel lymph node diagnostics.
Detection of the "true" sentinel lymph nodes, permitting correct staging of regional lymph nodes, is essential for management and prognostic assessment in malignant melanoma. In this study, it was prospectively evaluated whether simple temporary shielding of hot spots in lymphatic drainage areas could improve the accuracy of sentinel lymph node diagnostics. In 100 consecutive malignant melanoma patients (45 women, 55 men; age 11-91 years), dynamic and static lymphoscintigraphy in various views was performed after strict intracutaneous application of technetium-99m nanocolloid (40-150 MBq; 0.05 ml/deposit) around the tumour (31 patients) or the biopsy scar (69 patients, safety distance 1 cm). ⋯ In one of these patients, two additional sentinel lymph nodes (with metastasis) were detected. Overall, in 43/100 patients the temporary shielding yielded additional information, with sentinel lymph node metastases in 7%. In conclusion, when used in combination with dynamic acquisition in various views, temporary shielding of prominent hot spots in the drainage area of a malignant melanoma of the skin leads to an improvement in the accuracy of identification and localisation of sentinel lymph nodes by lymphoscintigraphy.
-
Eur. J. Nucl. Med. Mol. Imaging · Oct 2002
Clinical TrialPersistent non-specific FDG uptake on PET imaging following hip arthroplasty.
Hip arthroplasty is a common surgical procedure, but the diagnosis of infection associated with hip arthroplasty remains challenging. Fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) has been shown to be a promising imaging modality in settings where infection is suspected. However, inflammatory reaction to surgery can result in increased FDG uptake at various anatomic locations, which may erroneously be interpreted as sites of infection. ⋯ The average time interval in these patients was 114.8 months. It is concluded that following hip arthroplasty, non-specifically increased FDG uptake around the head or neck of the prosthesis persists for many years, even in patients without any complications. Therefore, to minimize the number of false-positive results for infection with PET studies obtained to evaluate a painful hip prosthesis, caution should be exercised when interpreting FDG uptake around the head or neck portion of the prosthesis.