The journal of supportive oncology
-
Randomized Controlled Trial
Use of heparin-coated central venous lines to prevent catheter-related bloodstream infection.
Bloodstream infections related to the use of central venous catheters are an important cause of patient morbidity, mortality, and increased health care costs. Catheter-related infection may be due to fibrin deposition associated with catheters. Interventions designed to decrease fibrin deposition have the potential to reduce catheter-related infections. ⋯ Six and seven patients experienced severe bleeding in the heparin-coated and control groups, respectively (P = 1.00). We did not observe heparin-induced thrombocytopenia. The use of heparin-coated catheters can be a safe and effective approach to the prevention of catheter-related bloodstream infection in patients with hematooncologic disease.