Journal of occupational and environmental hygiene
-
J Occup Environ Hyg · Jan 2008
Comparative Study Clinical TrialEffects of Hoods and Flame-Retardant Fabrics on WBGT Clothing Adjustment Factors.
Personal protective clothing (PPC) may include hoods and flame-retardant (FR) fabrics that may affect heat transfer and, thus, the critical wet bulb globe temperature (WBGT crit) to maintain thermal equilibrium. The purpose of this study was to compare the differences in WBGT crit for hooded vs. nonhooded versions of particle barrier and vapor barrier coveralls as well as for coveralls made of two flame-retardant fabrics (INDURA cotton and Nomex). Acclimated men (n = 11) and women (n = 4) walked on a treadmill in a climatic chamber at 180 W/m2 wearing four different ensembles: limited-use, particle barrier coveralls with and without a hood (Tyvek 1427), and limited-use vapor barrier coveralls with and without a hood (Tychem QC, polyethylene-coated Tyvek). ⋯ Hooded ensembles had a lower WBGT crit than the nonhooded ensembles. The difference suggested a clothing adjustment of 1 degrees C for hoods. There were no significant differences among the FR ensembles and cotton work cloths, and the proposed clothing adjustment for FR coveralls clothing is 0 degrees C.