Journal of occupational and environmental hygiene
-
J Occup Environ Hyg · Sep 2008
Filtration performance of NIOSH-approved N95 and P100 filtering facepiece respirators against 4 to 30 nanometer-size nanoparticles.
This study investigated the filtration performance of NIOSH-approved N95 and P100 filtering facepiece respirators (FFR) against six different monodisperse silver aerosol particles in the range of 4-30 nm diameter. A particle test system was developed and standardized for measuring the penetration of monodisperse silver particles. For respirator testing, five models of N95 and two models of P100 filtering facepiece respirators were challenged with monodisperse silver aerosol particles of 4, 8, 12, 16, 20, and 30 nm at 85 L/min flow rate and percentage penetrations were measured. ⋯ The two aerosols had the same effect across 20 nm and 30 nm sizes as shown by the absence of any significant (p = 0.163) interaction with particle sizes. In the case of P100 FFRs, a significant (p < 0.001) difference between NaCl and silver aerosol (20 nm and 30 nm) penetrations was observed for both respirator models tested. The filtration data for 4-30 nm monodisperse particles supports previous studies that indicate NIOSH-approved air-purifying respirators provide expected levels of filtration protection against nanoparticles.