Mathematical biosciences and engineering : MBE
-
Assessment of peripheral perfusion and comparison of surface and body core temperature (BST; BCT) are diagnostic cornerstones of critical care. Infrared non-contact thermometers facilitate the accurate measurement of BST. Additionally, a corrected measurement of BST on the forehead provides an estimate of BCT (BCT_Forehead). ⋯ In a multivariate analysis regarding CI_TD and including biometric data, BSTs and and their differences to core-temperatures (DCST), only higher temperatures on the forearm and the great toe, young age, low height and male gender were independently associated with CI_TD. The estimate of CI based on this model (CI_estimated) correlated with CI_TD (r = 0.594; p < 0.001). CI_estimated provided large ROC-areas under the curve (AUC) regarding the critical thresholds of CI_TD ≤ 2.5 L/min/m2 (AUC = 0.862) and CI_TD ≥ 5.0 L/min/m2 (AUC = 0.782). 1.) BCT_PiCCO, BCT_Ear and BCT_Bladder are interchangeable. 2.) BCT_Forehead significantly underestimates BCT by about 0.5° Celsius. 3.) All measured BSTs and DCSTs were significantly associated with CI_TD. 4.) CI_estimated is promising, in particular for the prediction of critical thresholds of CI.