To determine the oxygen outflow delivered by seven different models of manually operated self-inflating resuscitation bags (with and without an oxygen reservoir connected), which were tested using different oxygen supply rates without manipulating the bag, by simulating their use in patients breathing spontaneously. ⋯ Of the resuscitation bags studied, those that allow the connection of an oxygen reservoir must have this reservoir connected to the bag when used as a source of oxygen in nonintubated spontaneously breathing patients. All of the models studied should receive oxygen at a rate > 15 L/min. It is not safe to use manually operated self-inflating resuscitation bags for this purpose without knowing their characteristics.
-
To test the efficiency of the Bird Mark 7 ventilator adapted to deliver continuous positive airway pressure (CPAP) in noninvasive positive pressure ventilation. ⋯ The efficiency of Bird Mark 7 adaptation in offering CPAP was satisfactory at 5 and 10 cmH2O but insufficient at 15 cmH2O. If adapted as described in our study, the Bird Mark 7 might be an option for offering CPAP up to 10 cmH2O in areas where little or no equipment is available.
-
Insomnia and excessive sleepiness are common in the investigation of sleep-disordered breathing. Circadian rhythm sleep disorders are perhaps the most often overlooked conditions in the differential diagnosis of these symptoms. Circadian rhythm sleep disorders manifest as misalignment between the sleep period and the physical/social 24-h environmental cycle. ⋯ However, there are nine possible diagnoses, and all nine are of clinical interest. Since light is the principal cue used in synchronizing the biological clock, blind individuals and night-shift/swing-shift workers are more prone to develop circadian rhythm sleep disorders. In this article, the new international classification of circadian rhythm sleep disorders is reviewed.
-
Macrophage activation syndrome is a rare and potentially life-threatening disease. It occurs due to immune dysregulation manifested as excessive macrophage proliferation, typically causing hepatosplenomegaly, pancytopenia and hepatic dysfunction. ⋯ We recommend that macrophage activation syndrome be considered in the differential diagnosis of respiratory failure. Rapid diagnosis and treatment are essential to achieving favorable outcomes in patients with this syndrome.