Acta orthopaedica
-
Clinical Trial
Anterior knee pain following total knee replacement correlates with the OARSI score of the cartilage of the patella.
Attempts to relate patellar cartilage involvement to anterior knee pain (AKP) have yielded conflicting results. We determined whether the condition of the cartilage of the patella at the time of knee replacement, as assessed by the OARSI score, correlates with postsurgical AKP. ⋯ The depth and extent of the cartilage lesion of the knee-cap should be considered when deciding between the various options for treatment of the patella during knee replacement.
-
The mechanism of failure of metal-on-metal (MoM) total hip arthroplasty (THA) has been related to a high rate of metal wear debris, which is partly generated from the head-trunnion interface. However, it is not known whether implant fixation is affected by metal wear debris. ⋯ Most cups and stems were well-fixed at 1-5 years. However, at 2-5 years, 4 cups and 5 stems had TT migrations above the precision limits, but these patients had serum metal ion levels similar to those of patients without measurable migrations, and they were pain-free. Patients with serum metal ion levels > 7 µg/L had migrations similar to those in patients with serum metal ion levels < 7 µg/L. Metal wear debris does not appear to influence the fixation of hip components in large-head MoM articulations at medium-term follow-up.
-
Randomized Controlled Trial
Faster recovery without the use of a tourniquet in total knee arthroplasty.
Tourniquet application is still a common practice in total knee arthroplasty (TKA) surgery despite being associated with several adverse effects. We evaluated the effects of tourniquet use on functional and clinical outcome and on knee range of motion (ROM). ⋯ This study shows that TKA without the use of a tourniquet results in faster recovery in terms of better functional outcome and improved knee ROM. Furthermore, reduced pain and analgesic use were registered and no intraoperative difficulties were encountered.
-
We previously evaluated a new uncemented femoral stem designed for elderly patients with a femoral neck fracture and found stable implant fixation and good clinical results up to 2 years postoperatively, despite substantial periprosthetic bone mineral loss. We now present the medium-term follow-up results from this study. ⋯ In this medium-term follow-up, the stem remained firmly fixed in bone despite considerable periprosthetic bone mineral loss. However, this bone loss might explain the high number of late-occurring periprosthetic fractures. Based on these results, we would not recommend uncemented femoral stems for the treatment of femoral neck fractures in the elderly.