Limited knowledge exists regarding the forces which act on devices implanted to the heart's mitral valve. Developing a transducer to measure the peak force magnitudes, time rates of change, and relationship with left ventricular pressure will aid in device development. A novel force transducer was developed and implanted in the mitral valve annulus of an ovine subject. ⋯ Combined, this study provides the first quantitative assessment of septal-lateral and transverse forces within the contractile mitral annulus. The developed transducer was successful in measuring these forces whose methods may be extended to future studies. Upon additional investigation, these data may contribute to the safer development and evaluation of devices aimed to repair or replace mitral valve function.
-
Journal of biomechanics · May 2012
Flow resistance analysis of extracranial-to-intracranial (EC-IC) vein bypass.
Although brain bypass surgery has often been selected to treat internal carotid arteries (ICA) which are restricted by aneurysm or artery stenosis, its effectiveness has not been quantitatively evaluated. The purpose of this study is to propose an innovative approach for the evaluation of brain extracranial-to-intracranial (EC-IC) vein bypass surgery, based on the analysis of flow resistance in vein bypasses and within their contralateral carotid arteries through the use of computational fluid dynamics (CFD). Seven patients who underwent vein bypass surgery were examined with the use of high-resolution; computed tomography angiogram (CTA). ⋯ For the vein bypass, an average value of A was 0.0143 Pa/(ml/min)² and B 3.402 Pa/(ml/min), which was approximately that of a healthy ICA. However, in the case of a bypass utilising a venous conduit possessing a large-sized valve or existing size alteration, the flow resistance in that bypass would be higher than those found in the healthy ICA. An imbalance of flow resistances may impose conditions that could predispose hemodynamic failure or distal aneurysm development.
-
Journal of biomechanics · May 2012
Our capricious vessels: The influence of stent design and vessel geometry on the mechanics of intracranial aneurysm stent deployment.
There is a growing interest in virtual tools to assist clinicians in evaluating different procedures and devices for endovascular treatment. In the present study we use finite element analysis to investigate the influence of stent design and vessel geometry for stent assisted coiling of intracranial aneurysms. Nine virtual stenting procedures were performed: three nitinol stent designs ((i) an open cell stent resembling the Neuroform, (ii) a generic stiff and (iii) a more flexible closed cell design), were deployed in three patient-specific cerebral aneurysmatic vessels. ⋯ The results suggest that the open cell design better covers the aneurysm neck (11.0±1.1%) compared to both the stiff (7.8±1.6%) and flexible (8.7±1.6%) closed cell stents, and induces less straightening of the vessel (-5.1±1.6% vs. -42.9±9.8% and -26.9±11.9% ). The open cell design has, however, less struts apposing well to the vessel wall (56.0±6.4%) compared to the flexible (73.4±4.6%) and stiff (70.4±5.1%) closed cell design. With the presented study, we hope to contribute to and improve aneurysm treatment, using a novel patient specific environment as a possible pre-operative tool to evaluate mechanical stent behavior in different vascular geometries.