EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
-
The STEALTH (STent Eluting A9 BioLimus Trial in Humans) trial was the first-in-man study to assess the safety and efficacy of the bioabsorbable-polymer-coated Biolimus A9-eluting BioMATRIX-Stent, as compared to a bare metal stent control (S-Stent). ⋯ In this first-in-man feasibility trial, the bioabsorbable-polymer-coated Biolimus A9-eluting stent demonstrated superior efficacy in reducing 6-month in-stent and in-lesion late loss and percent diameter stenosis, with clinical safety similar to bare metal control stents.