Innovations : technology and techniques in cardiothoracic and vascular surgery
-
Innovations (Phila) · Mar 2018
Comparative StudyEvolution of Minimally Invasive Coronary Artery Bypass Grafting: Learning Curve.
Minimally invasive coronary surgery approach for coronary artery bypass grafting is a safe and reproducible procedure for multivessel revascularization. This study reviewed a single surgeon's experience with minimally invasive coronary surgery coronary artery bypass grafting, including operative time, number of bypasses, and conversion to sternotomy. ⋯ As experience with minimally invasive coronary surgery coronary artery bypass grafting increased, the ideal sequence of steps to optimize surgical outcome was defined. The number of bypassed vessels increased and the operative time and conversion to sternotomy decreased.
-
Innovations (Phila) · Mar 2018
A Phase 1 Study of a Novel Bidirectional Perfusion Cannula in Patients Undergoing Femoral Cannulation for Cardiac Surgery.
Leg ischemia is a serious complication of femoral artery cannulation. The primary aim of this study was to assess the safety and efficacy of a novel bidirectional femoral arterial cannula (Sorin Group USA, a wholly owned subsidiary of LivaNova PLC, Arvada, CO USA) that provides both antegrade and retrograde flow, in patients undergoing peripheral cannulation for cardiopulmonary bypass during cardiac surgery. ⋯ This study demonstrates that in patients undergoing femoral arterial cannulation for cardiopulmonary bypass during cardiac surgery, the use of a novel bidirectional cannula is safe and easy to insert and provides stable distal perfusion of the cannulated limb. Use of the device should largely obviate the need to insert a separate downstream perfusion cannula or use other techniques to protect against lower limb ischemia. Further research on a larger scale and in different patient populations is now warranted.
-
Innovations (Phila) · Mar 2018
Observational StudyEpicardial, Biatrial Ablation With Integrated Uni-bipolar Radiofrequency Technology in Stand-alone Persistent Atrial Fibrillation.
Although minimally invasive approaches for surgical treatment of stand-alone atrial fibrillation have gained popularity for the past decade, ablation technology and extensive lesion sets play a major role in the achievement of a successful procedure, especially in presence of persistent and long-standing persistent atrial fibrillation. We evaluated clinical outcomes after totally endoscopic biatrial epicardial ablation of persistent atrial fibrillation with a novel integrated uni-bipolar radiofrequency device. ⋯ Integrated uni-bipolar radiofrequency ablation technology showed to be effective for the surgical treatment of atrial fibrillation with a total endoscopic approach. A versapolar suction device with extensive right-left atrial lesion set may further improve outcomes in patients with nonparoxysmal atrial fibrillation.