Clinical research in cardiology : official journal of the German Cardiac Society
-
Rapid ventricular pacing (RVP) is an established technique to temporarily reduce left ventricular output during transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the impact of RVP on microvascular tissue perfusion (MTP) in patients undergoing TAVI. ⋯ The study demonstrates a time-dependent effect of RVP on microflow, leading to 50 and 25 % of baseline at 8 and 18 s of RVP, respectively. In a substantial proportion of patients, RVP is associated with microcirculatory arrest and a delayed recovery of microflow. Although the impact of these findings on outcome is yet unclear, TAVI operators should be aware of the potentially adverse effects of even short periods of RVP.