Comparative StudyCardiac MRI: comparison between single-shot fast spin echo and conventional spin echo sequences in the morphological evaluation of the ventricles.
Black blood single shot FSE sequences (Nffse) employ 180 degrees RF refocalisation pulses preceded by an inversion RF double pulse associated to presaturation pulses. The latter produce signal void of the external volume, and possible reduction of the field of view without wrap-around artifacts along the phase coding direction. The aim of our study was to compare the diagnostic possibilities of the Nffse sequences with those of conventional SE study of cardiac morphology. ⋯ The Nffse sequences provide a number of gated multiphase-multislice images, similar to that obtained by conventional SE sequences, in one breath-hold time interval. Due to high intrinsic contrast and reduction of motion artifacts, the Nffse sequences allow a good evaluation of the ventricular morphology and subepicardial and paracardiac adipose tissue. Image quality can be suboptimal due to blurring artifacts. Therefore Nffse sequences can be advantageously employed to image patients with suspected right ventricular arrhythmogenic dysplasia, whenever conventional SE images exhibit substandard quality.