Journal of medical toxicology : official journal of the American College of Medical Toxicology
-
Though the use of small bolus doses of vasopressors, termed "push dose pressors," has become common in emergency medicine, data examining this practice are scant. Push dose pressors frequently involve bedside dilution, which may result in errors and adverse events. The objective of this study was to assess for instances of human error and adverse hemodynamic events during push dose pressor use in the emergency department. ⋯ Human errors and adverse hemodynamic events were common with the use of push dose pressors in the emergency department. Adverse hemodynamic events were more common than in previous studies. Future research should determine if push dose pressors improve outcomes and if so, how to safely implement them into practice.