The objective of this study was to assess the feasibility of DDD pacing from a standard single-pass VDD pacemaker system. Over the past 2 decades significant advances have been made in the development of single-pass VDD pacing systems. These have been shown in long-term prospective studies to effectively preserve atrioventricular (AV)synchrony in patients with AV block and normal sinus node function. ⋯ Despite higher than usual thresholds via the atrial dipole, pacemaker telemetry revealed < 10% use of atrial pacing dipole over a 12-month period, which would minimally deplete the pacemaker's battery. In addition, the telemetry confirmed appropriate sensing and pacing of the atrial dipole throughout the study period. At this time such systems can serve as back-up DDD pacing systems with further refinements required to optimize atrial thresholds in all patients.
-
The totally implantable catheter system has gained popularity as venous access when prolonged treatment is needed. Despite its frequent use, intravascular fracture and embolization of catheter fragments from implantable venous port-catheter systems present a rare but potentially life-threatening complication. Any implanted catheters should therefore be removed after completion of the treatment or the system's integrity should be monitored on a regular basis. ⋯ A chest radiograph showed a normal location of the port-system, but the distal fragment of the catheter had embolized into the right ventricle. The embolized fragment was extracted with a gooseneck snare technique and the reservoir of the system was removed under local anesthesia without any complications. The patient was free of symptoms at 7 seven months follow-up.
-
The authors encountered a very rare case of paradoxical brain embolism resulting from pulmonary arteriovenous fistula and coincident pulmonary embolism. Enhanced computed tomography was useful for diagnosing this infrequent condition.
-
Review Case Reports
Inferior vena cava filter ensnarement by central line guide wires--a report of 4 cases and brief review.
Ensnarement of inferior vena cava filters with central line guide wires is an infrequent complication that has been sporadically reported. The authors present 4 patients who experienced this complication. They review the literature, make recommendations to avoid this preventable complication, and recommend what to do once the complication occurs.
-
The clinical features with particular reference to tamponade and mediastinal adenopathy were studied in tuberculous pericardial effusion. Tamponade is a frequent complication and the recognition of tuberculous etiology can be difficult. Involvement of the pericardium is mostly from mediastinal lymph nodes that have not been studied. ⋯ Mediastinal nodes were enlarged in all and only with tuberculosis and not with viral/idiopathic effusion. Nodes disappeared or regressed with treatment. In the appropriate clinical context, mediastinal lymph node enlargement on chest computed tomography along with a strongly positive skin test results could help in the diagnosis of a tuberculous etiology of pericardial effusion.