The Journal of hand surgery, European volume
-
J Hand Surg Eur Vol · Sep 2013
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures.
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. ⋯ In 31.3% of the surgeries a misplacement of screws was detected and correction was done immediately. C-arm CT imaging can easily be integrated in the normal course of surgery. As a complement to the standard 2D-fluoroscopy, the C-arm CT is a useful tool to evaluate the quality of osteosynthesis.
-
J Hand Surg Eur Vol · Sep 2013
The incidence of ulnocarpal complaints after distal radial fracture in relation to the fracture of the ulnar styloid.
Two hundred distal radial fractures, with a mean follow up of 20 months (range 6-49), were divided into three groups according to the presence and healing status of an ulnar styloid fracture. The patients underwent both clinical and radiological examination and completed two different questionnaires. ⋯ The authors encountered significantly higher pain scores (ulnar sided pain p = 0.012), a higher rate of DRUJ instability (p = 0.032), a greater loss of motion and grip strength (p = 0.001), and a poorer clinical outcome in cases with an ulnar styloid fracture, but no differences were apparent when those with healed ulnar styloid fractures or ulnar styloid nonunions were compared (p > 0.05). The investigators propose that the incidence of ulnocarpal complaints following distal radial fracture depends on the presence but not the healing status of an ulnar styloid fracture.
-
The Pulvertaft weave has been the standard tendon junction technique used both in tendon transfers and tendon grafts. A limitation of this repair is the sequential failure of stabilizing sutures, rather than the tendon. A novel loop weave is described and compared with the Pulvertaft weave in biomechanical performance. ⋯ The loop weave demonstrated significantly higher mean initial failure and ultimate strengths. Tensile loads required to elongate the loop weave by 4, 6, and 8 mm were significantly higher, while more displacement was associated with the Pulvertaft repair under the application of 50, 75, and 100 N tensile loads. This study demonstrates favourable biomechanical characteristics of the new loop weave technique.