Meta Analysis Comparative StudyPercutaneous pinning versus volar locking plate internal fixation for unstable distal radius fractures: a meta-analysis.
This meta-analysis compared outcomes between percutaneous pinning/wiring and open reduction internal fixation (ORIF) with locking plates for treatment of unstable distal radius fractures. Medline, Cochrane, EMBASE, and Google Scholar were searched through December 30, 2015. Twenty randomised controlled trials (RCTs) and non-randomised two-arm studies were included. ⋯ Supination and grip strength were better with ORIF. Radiographically, ulnar variation was greater with pinning/wiring. These results suggest that ORIF/plating is the preferred method of managing unstable distal radius fractures.
-
J Hand Surg Eur Vol · Feb 2018
Meta AnalysisFunctional outcomes of distal radius fractures with and without ulnar styloid fractures: a meta-analysis.
The aim of this meta-analysis was to compare the functional outcomes of patients with a distal radius fracture with and without a concomitant fracture of the ulnar styloid process. A systematic literature search was performed to identify all studies comparing patients with a distal radius fracture with and without an ulnar styloid process fracture. The initial search revealed 511 articles, of which 12 articles with a total of 2243 patients were included; 1196 patients with and 1047 patients without an ulnar styloid process fracture. ⋯ This difference is less than 10 and therefore not clinically important. No significant difference was found in Patient-Rated Wrist Evaluation scores, range of motion, grip strength, visual analogue scale pain scores, ulnar-sided wrist pain and distal radio-ulnar joint instability between patients with and without an ulnar styloid process fracture after 1 year of follow-up. Moreover, no significant differences were found between ulnar styloid base and nonbase fractures.
-
The purpose was to determine if smartphone photography is a reliable tool in measuring wrist movement. Smartphones were used to take digital photos of both wrists in 32 normal participants (64 wrists) at extremes of wrist motion. The smartphone measurements were compared with clinical goniometry measurements. ⋯ The Bland-Altman plots demonstrated 29-31 of 32 smartphone measurements were within the 95% confidence interval of the clinical measurements for all positions of the wrists. There was high reliability between the photography taken by the volunteer and researcher, as well as high inter-observer reliability. Smartphone digital photography is a reliable and accurate tool for measuring wrist range of motion.