Comparison of hemodynamic effects of enhanced external counterpulsation and intra-aortic balloon pumping in patients with acute myocardial infarction.
This study compared the hemodynamic effects of enhanced external counterpulsation and intra-aortic counterpulsation in patients with acute myocardial infarction. Results demonstrated similarity between these 2 methods, except enhanced external counterpulsation had a transient effect of increasing right atrial pressure, pulmonary capillary wedge pressure, and cardiac index.
-
A retrospective, transesophageal study of 51 consecutive patients receiving a left ventricular (LV) assist device (AD) over a 2-year period showed that LVAD-associated LV thrombosis (16%) was predicted by acute myocardial infarction, atrial cannulation, and postimplantation bleeding, and was associated with a fourfold increased risk of stroke compared with patients without thrombosis. LV cannulation, when using short-term LVADs, may decrease the incidence of LV thrombosis, and early transition to Heartmate-LVAD support may improve outcome.
-
Antiarrhythmic drugs, mainly amiodarone and sotalol, radiofrequency catheter ablation, and the implantable cardioverter defibrillator (ICD) are the 3 therapeutic options in patients with sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Idiopathic VT, incessant VT, frequently recurring, hemodynamically stable VT, and VT based on bundle branch reentry, are candidates for radiofrequency catheter ablation. Patients with high-risk ventricular tachyarrhythmias should receive ICDs as initial therapy. ⋯ The problem in the CIDS trial in this regard was the recruitment of patients in whom the inclusion criteria were met by the arrhythmias induced during the electrophysiology stimulation study, but which did not exist in real life. In addition CIDS included 14% of patients with (1) undocumented syncope and inducible monomorphic sustained VT; or (2) long runs of spontaneous nonsustained VT. Under these circumstances, the therapeutic implications of AVID remain unchallenged.
-
Several independent studies suggest that resynchronization therapy--achieved by left- or biventricular pacing--improves hemodynamics in heart failure patients with interventricular conduction disturbances. Delivery of this new therapy in an effective and minimally invasive manner presents technical challenges, as transvenous access to the left ventricle is required. Since 1999, a novel over-the-wire approach combining standard pacing lead and angioplasty technology has been evaluated in several European countries. ⋯ Once the coronary sinus was found, the implant success rate was 92%. One lead dislodgment and 2 cases of phrenic nerve stimulation were reported. We conclude that the new EASYTRAK lead design for transvenous left ventricular lead implantation seems to be a suitable and safe tool for delivering resynchronization therapy to heart failure patients.
-
Cardiac pacing remains one of the most effective means for preventing torsade de pointes in patients with long QT syndrome (LQTS). However, fatal arrhythmias may occur despite combined therapy with beta blockers and pacing, and it is possible that failure of cardiac pacing for preventing arrhythmias in the long run is related (at least in part) to suboptimal pacemaker programming. ⋯ Unfortunately, properly functioning pacemakers cannot be expected to prevent postextrasystolic pauses. The use of a pause-prevention pacing algorithm-rate smoothing-for preventing pause-dependent torsade de pointes is described in 12 patients with cardiac arrest or syncope due to congenital LQTS who were followed for 21 +/- 11 months.