The American journal of cardiology
-
Randomized Controlled Trial Clinical Trial
A dose-finding study of the hemodynamic effect of isosorbide dinitrate spray in congestive heart failure.
A dose-finding study of the hemodynamic effect of a new formulation of isosorbide dinitrate (ISDN) spray was performed in 12 patients with chronic congestive heart failure. Doses of 1.25, 2.5, 5.0 mg and placebo, as 1 squirt, were randomly given to all patients. Hemodynamic measurements were performed by a Swan-Ganz catheter before and at 30 seconds and 1, 5, 10, 20 and 30 minutes after drug administration and every 30 minutes thereafter, until return of hemodynamic variables to baseline. ⋯ Near maximal effect was achieved by the 2.5-mg dose. Thus, 2.5 mg of ISDN spray (new formulation) dose. Thus, 2.5 mg of ISDN spray (new formulation) produces rapid, near-maximal hemodynamic improvement in patients with congestive heart failure.
-
The hemodynamic manifestations of the Valsalva maneuver are in part the result of changes in the venous return accompanying changes in intrathoracic pressure. Doppler echocardiography was performed during Valsalva maneuver in 13 normal subjects. Superior vena cava flow velocities and flow velocity integrals were measured in all 13 subjects. ⋯ With release of the maneuver (phase III), there was a sudden significant increase in flow velocity integral (61 +/- 2 cm, p = 0.005 vs phase II) and superior vena cava lumen diameter. Subsequently, superior vena cava flow velocity integral returned to baseline values. This study suggests that one of the ways in which the Valsalva maneuver leads to decreased venous return may be by direct external compression of the superior vena cava.
-
There are few data on oxygen transport in cardiogenic shock after acute myocardial infarction. This prospective study examined oxygen transport variables in 19 such patients and assessed their responses to treatment. Femoral and pulmonary arterial catheters were inserted before any therapy except correction of hypoxemia by mechanical ventilation in 8 patients, defibrillation (3 patients) or pacing (5 patients). ⋯ There was no correlation between cuff systolic blood pressure and mean arterial pressure before or after resuscitation. Thirteen patients survived to hospital discharge. When cardiogenic shock responds to treatment, large increases in DO2 lead to small increases in VO2 but large increases in mixed venous oxygen saturation, reflecting improved tissue oxygen availability.
-
Comparative Study
Effect of empiric antiarrhythmic therapy in resuscitated out-of-hospital cardiac arrest victims with coronary artery disease.
The effect of empiric antiarrhythmic therapy with quinidine and procainamide on long-term mortality was examined in 209 patients with coronary artery disease resuscitated after out-of-hospital cardiac arrest. The antiarrhythmic agent used was determined by the patient's private physician without knowledge of the study ambulatory electrocardiogram. ⋯ The 2-year total survival rate for the quinidine, procainamide and nontreated patients was 61, 57 and 71% (p less than 0.05), and for sudden death was 69, 69 and 89% (p less than 0.01), respectively. These observations suggest that empiric antiarrhythmic therapy in survivors of out-of-hospital cardiac arrest did not affect total mortality and was associated with an increased frequency of sudden death.
-
Comparative Study
Acute changes in pacing threshold and R- or P-wave amplitude during permanent pacemaker implantation.
This study examines the changes in pacing threshold and R- or P-wave amplitude during the first 30 minutes after implantation of tined and screw-in leads. The leads examined were those of 1 manufacturer (Medtronic) and consisted of 3 ventricular pacing leads (model numbers 6957 unipolar screw-in [11 patients], 6961 unipolar tined [12 patients] and 6962 bipolar tined [7 patients]) and 1 atrial lead (model number 6957J unipolar screw-in [10 patients]). After optimal lead position was obtained fluoroscopically in the right ventricular apex or right atrium, the pacing threshold and R- or P-wave amplitudes were measured at 5-minute intervals for 30 minutes. ⋯ There was a significant acute increase in R-wave size with the ventricular screw-in lead that peaked 20 minutes after lead implantation (11.9 +/- 3.0 to 14.7 +/- 4.1 mV; p less than 0.001). The atrial screw-in lead behaved in a manner identical to its counterpart in the ventricle. In conclusion, there are acute changes in the pacing threshold and R- or P-wave amplitude obtained with tined and screw-in pacing leads.(ABSTRACT TRUNCATED AT 250 WORDS)