Circulation. Arrhythmia and electrophysiology
-
Circ Arrhythm Electrophysiol · Apr 2011
Meta AnalysisAdditional ablation of complex fractionated atrial electrograms after pulmonary vein isolation in patients with atrial fibrillation: a meta-analysis.
The efficacy of additional complex fractionated atrial electrogram (CFAE) ablation after pulmonary vein antrum isolation (PVAI) in patients with atrial fibrillation (AF) remains controversial. This meta-analysis was performed to assess the additional efficacy of CFAEs ablation after a single procedure without antiarrhythmic drugs. ⋯ Adjuvant CFAE ablation in addition to standard PVAI increases the rate of long-term sinus rhythm maintenance in nonparoxysmal AF patients after a single procedure without antiarrhythmic drugs but does not provide additional benefit to sinus rhythm maintenance in paroxysmal AF patients.
-
Circ Arrhythm Electrophysiol · Apr 2011
A critical analysis of the scientific evidence behind international guidelines related to cardiac arrhythmias.
Guidelines have become very important in assisting with decision making in clinical practice. However, few studies have analyzed the level of evidence (LOE) underlying guidelines critically. This study aims to assess the accuracy of the referenced literature that has led to recommendations with a level of evidence A (LOE-A) rating. ⋯ Our findings raise the question of the accuracy of LOE-A in medical guidelines in general and highlight the importance of a critical use of all recommendations. Moreover, they underline the need for improving the guideline-writing process. Further randomized double-blinded and/or crossover-designed studies should focus on areas with a gap in the evidence, such as existing but not yet convincing (LOE-B) or conflicting (Class II) evidence.
-
Circ Arrhythm Electrophysiol · Apr 2011
Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: results of a pilot study.
Luminal esophageal temperature (LET) monitoring is one strategy to minimize esophageal injury during atrial fibrillation ablation procedures. However, esophageal ulceration and fistulas have been reported despite adequate LET monitoring. The objective of this study was to assess a novel approach to LET monitoring with a deflectable LET probe on the rate of esophageal injury in patients undergoing atrial fibrillation ablation. ⋯ A strategy of optimal LET probe placement using a deflectable LET probe and intracardiac echocardiography guidance, combined with cessation of radiofrequency ablation with a 2°C rise in LET, may reduce esophageal thermal injury during left atrial ablation procedures.