International journal of computer assisted radiology and surgery
-
Int J Comput Assist Radiol Surg · Apr 2016
Comparative StudyComparison of anterograde versus retrograde percutaneous screw fixation of anterior column acetabular fractures.
Percutaneous screw fixation is an effective technique in addressing minimally displaced anterior column acetabular fractures. The aim of this study is to evaluate the ease of percutaneous screw insertion for acetabular anterior column fracture, as it pertains to anterograde versus retrograde insertion techniques. ⋯ In our analysis, we found two areas for effective percutaneous anterograde insertion and one area for effective retrograde insertion. They both possess geometries with different shapes. Additionally, the area of anterograde insertion is larger than the retrograde area of insertion. The limitations in screw positions were shown in the AP, inlet, outlet, iliac oblique, obturator oblique, and lateral views. The direction range between superior and inferior and between medial and lateral were measured and recorded. In area of anterograde, the angle between the superior and inferior limits was 29.2° ± 2.7°, while the angle limit between medial and lateral was 18.5° ± 1.8°. In area of retrograde, the angle between the superior and inferior limits was 8.32° ± 1.3°, while the angle limit between medial and lateral was 7.5° ± 0.8°