Because of the high glucose metabolism in normal brain tissue 18F-FDG is not the ideal tracer for the detection of gliomas. Methyl-11C-l-methionine (11C-MET) is better suited for imaging the extent of gliomas, because it is transported specifically into tumors but only insignificantly into normal brain. 3'-Deoxy-3'-18F-fluorothymidine (18F-FLT) has been introduced as a proliferation marker in a variety of neoplasias and has promising potential for the detection of brain tumors, because its uptake in normal brain is low. Additionally, the longer half-life might permit differentiation between transport and intracellular phosphorylation. ⋯ 18F-FLT is a promising tracer for the detection and characterization of primary central nervous system tumors and might help to differentiate between low- and high-grade gliomas. 18F-FLT uptake is mainly due to increased transport, but irreversible incorporation by phosphorylation might also contribute. In some tumors and tumor areas, 18F-FLT uptake is not related to 11C-MET uptake. In view of the high sensitivity and specificity of 11C-MET PET for imaging of gliomas, it cannot be excluded that 18F-FLT PET was false positive in these areas. However, the discrepancies observed for the various imaging modalities (18F-FLT and 11C-MET PET as well as gadolinium-enhanced MRI) yield complementary information on the activity and the extent of gliomas and might improve early evaluation of treatment effects, especially in patients with high-grade gliomas. Further studies are needed, including coregistered histology and kinetic analysis in patients undergoing chemotherapy.
-
This article reports the results of performance measurements obtained for the lutetium oxyorthosilicate (LSO)-based whole-body PET/CT scanner Biograph 16 HI-REZ with the National Electrical Manufacturers Association (NEMA) NU 2-2001 standard. The Biograph 16 HI-REZ combines a multislice (16-slice) spiral CT scanner with a PET scanner composed of 24.336 LSO crystals arranged in 39 rings. The crystal dimensions are 4.0x4.0x20 mm3, and the crystals are organized in 13x13 blocks coupled to 4 photomultiplier tubes each. The 39 rings allow the acquisition of 81 images 2.0 mm thick, covering an axial field of view of 162 mm. The low- and high-energy thresholds are set to 425 and 650 keV, respectively, acquiring data within a 4.5-ns-wide coincidence window. ⋯ The new integrated PET/CT system Biograph 16 HI-REZ has good overall performance, with, in particular, a high resolution, a low scatter fraction, and a very good NEC response.