Journal of nuclear medicine : official publication, Society of Nuclear Medicine
-
Dopamine transporter (DAT) imaging with (123)I-FP-CIT ((123)I-N-omega-fluoropropyl-2beta-carbomethoxy-3beta-(4-iodophenyl)nortropane) SPECT is frequently used to detect loss of nigrostriatal cells in parkinsonism. Recent (123)I-beta-CIT ((123)I-2beta-carbomethoxy-3beta-(4-iodophenyl)tropane) studies have shown a significant increase in striatal-to-nonspecific beta-CIT binding ratios after treatment with selective serotonin reuptake inhibitors (SSRIs). Due to similarities between (123)I-beta-CIT and (123)I-FP-CIT (both are derived from cocaine and show relatively high affinity for the DAT and the serotonin transporter [SERT]), we hypothesized that quantification of striatal (123)I-FP-CIT binding may be influenced by SSRIs. Moreover, we hypothesized that (123)I-FP-CIT in humans binds not only to DATs but also to central and peripheral SERTs. ⋯ In this study we show that the quantification of striatal (123)I-FP-CIT binding to DAT is significantly increased by the SSRI paroxetine in humans. To our knowledge, this is the first study which shows that (123)I-FP-CIT binds in vivo in humans not only to DATs but also to central SERTs and SERTs in lung tissue.
-
Cigarette smoke is thought to promote local lung inflammation that leads to lung dysfunction. Lung neutrophilic inflammation is known to result in increased pulmonary uptake of (18)F-FDG. Using a sheep model of localized exposure to cigarette smoke, in this study we tested whether PET-imaged changes in regional intrapulmonary distribution of (18)F-FDG uptake are related to changes in regional lung function as assessed with the infused (13)NN-saline method. ⋯ Substantial interanimal variability and spatial heterogeneity in lung function and (18)F-FDG uptake seem to characterize the response to smoke exposure. The highest levels of local (18)F-FDG uptake were associated with differences in V/Q matching and shunt fraction among animals. The data also suggest that preexisting heterogeneity in V/Q could have been responsible for the large interanimal variability by affecting the heterogeneity and strength of the acute response to smoke inhalation.
-
Results from a new PET/CT scanner using lutetium-yttrium oxyorthosilicate (LYSO) crystals for the PET component are presented. This scanner, which operates in a fully 3-dimensional mode, has a diameter of 90 cm and an axial field of view of 18 cm. It uses 4 x 4 x 22 mm(3) LYSO crystals arranged in a pixelated Anger-logic detector design. This scanner was designed to perform as a high-performance conventional PET scanner as well as provide good timing resolution to operate as a time-of-flight (TOF) PET scanner. ⋯ The Gemini TF whole-body scanner represents the first commercially available fully 3-dimensional PET scanner that achieves TOF capability as well as conventional imaging capabilities. The timing resolution is also stable over a long duration, indicating the practicality of this device. Excellent image quality is achieved for whole-body studies in 10-30 min, depending on patient size. The most significant improvement with TOF is seen for the heaviest patients.