Journal of nuclear medicine : official publication, Society of Nuclear Medicine
-
The use of positron emitter-labeled compounds for somatostatin receptor imaging (SRI) has become attractive because of the prospect of improved spatial resolution, accelerated imaging procedures, and the ability to quantify tissue radioactivity concentrations. This paper provides results from first-in-humans use of (64)Cu-DOTATATE, an avidly binding somatostatin receptor ligand linked to a radioisotope with intermediate half-life and favorable positron energy (half-life, 12.7 h; maximum positron energy, 0.653 MeV). ⋯ This first-in-humans study supports the clinical use of (64)Cu-DOTATATE for SRI with excellent imaging quality, reduced radiation burden, and increased lesion detection rate when compared with (111)In-diethylenetriaminepentaacetic acid-octreotide.
-
Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory motion correction using simultaneous PET/MRI to demonstrate initial results in phantoms, rabbits, and nonhuman primates and discusses the prospects for clinical application. ⋯ Tagged MRI motion correction in simultaneous PET/MRI significantly improves lesion detection compared with respiratory gating and no motion correction while reducing radiation dose. In vivo primate and rabbit studies confirmed the improvement in PET image quality and provide the rationale for evaluation in simultaneous whole-body PET/MRI clinical studies.
-
The clinical performance of the Duke Endocarditis Service criteria to establish the diagnosis of infectious endocarditis (IE) can be improved through functional imaging procedures such as radiolabeled leukocytes ((99m)Tc-hexamethylpropyleneamine oxime [HMPAO]-labeled white blood cells [WBC]). ⋯ Our results demonstrate the ability of (99m)Tc-HMPAO-WBC scintigraphy to reduce the rate of misdiagnosed cases of IE when combined with standard diagnostic tests in several situations: when clinical suspicion is high but echocardiographic findings are inconclusive; when there is a need for differential diagnosis between septic and sterile vegetations detected at echocardiography; when echocardiographic, laboratory, and clinical data are contradictory; and when valve involvement (especially of a prosthetic valve) needs to be excluded during febrile episodes, sepsis, or postsurgical infections.