Journal of nuclear medicine : official publication, Society of Nuclear Medicine
-
The joint maximum-likelihood reconstruction of activity and attenuation (MLAA) for emission-based attenuation correction has regained attention since the advent of time-of-flight PET/MR imaging. Recently, we improved the performance of the MLAA algorithm using an MR imaging-constrained gaussian mixture model (GMM). In this study, we compare the performance of our proposed algorithm with standard 4-class MR-based attenuation correction (MRAC) implemented on commercial systems. ⋯ The proposed MLAA algorithm is promising for accurate derivation of attenuation maps on time-of-flight PET/MR systems.
-
Comparative Study
64Cu-DOTATATE PET for Neuroendocrine Tumors: A Prospective Head-to-Head Comparison with 111In-DTPA-Octreotide in 112 Patients.
Neuroendocrine tumors (NETs) can be visualized using radiolabeled somatostatin analogs. We have previously shown the clinical potential of (64)Cu-DOTATATE in a small first-in-human feasibility study. The aim of the present study was, in a larger prospective design, to compare on a head-to-head basis the performance of (64)Cu-DOTATATE and (111)In-diethylenetriaminepentaacetic acid (DTPA)-octreotide ((111)In-DTPA-OC) as a basis for implementing (64)Cu-DOTATATE as a routine. ⋯ With these results, we demonstrate that (64)Cu-DOTATATE is far superior to (111)In-DTPA-OC in diagnostic performance in NET patients. Therefore, we do not hesitate to recommend implementation of (64)Cu-DOTATATE as a replacement for (111)In-DTPA-OC.
-
Simultaneous PET and MR imaging is a promising new technique allowing the fusion of functional (PET) and anatomic/functional (MR) information. In the thoracic-abdominal regions, respiratory motion is a major challenge leading to reduced quantitative and qualitative image accuracy. Correction methodologies include the use of gated frames that lead to low signal-to-noise ratio considering the associated low statistics. More advanced correction approaches, previously developed for PET/CT imaging, consist of either registering all the reconstructed gated frames to the reference frame or incorporating motion parameters into the iterative reconstruction process to produce a single motion-compensated PET image. The goal of this work was to compare these two—previously implemented in PET/CT—correction approaches within the context of PET/MR motion correction for oncology applications using clinical 4-dimensional PET/MR acquisitions. Two different correction approaches were evaluated comparing the incorporation of elastic transformations extracted from 4-dimensional MR imaging datasets during PET list-mode image reconstruction to a postreconstruction image-based approach. ⋯ Our results demonstrate significant respiratory motion compensation using both methods, with superior results from a 4D PET RS approach.
-
The rupture of vulnerable atherosclerotic plaques that lead to stroke and myocardial infarction may be induced by macrophage infiltration and augmented by the expression of integrin αvβ3. Indeed, atherosclerotic angiogenesis may be a promising marker of inflammation. In this study, an engineered integrin αvβ3-targeting PET probe, (64)Cu-NOTA-3-4A, derived from a divalent knottin miniprotein was evaluated in a mouse model for carotid atherosclerotic plaques. ⋯ (64)Cu-NOTA-3-4A demonstrates specific accumulation in carotid atherosclerotic plaques in which macrophage infiltration and angiogenesis are responsible for elevated integrin αvβ3 levels. Therefore, (64)Cu-NOTA-3-4A may demonstrate clinical utility as a PET probe for atherosclerosis imaging or for the evaluation of therapies used to treat atherosclerosis.
-
In high-activity radioiodine therapies for differentiated thyroid cancer, blood dosimetry has been developed to estimate the maximum tolerable activity (MTA) of (131)I that can be safely administered without leading to toxic effects. The reference protocol involves a series of both blood sampling (BS) and whole-body counting (WC) over a period of several days. The aim of this retrospective study was to identify simplified protocols without an appreciable loss of accuracy. ⋯ The pretherapy blood dosimetry protocol can be substantially shortened and may be beneficial to patients and patient management while reducing the radiation exposure to medical staff.