Injury
-
The purpose of this study was to examine the screw trajectory of ten commercially available distal tibia plates and compare them to common fracture patterns seen in OTA C type pilon fractures to determine their ability to stabilize the three most common fracture fragments while buttressing anterolateral zones of comminution. ⋯ Level IV.
-
Observational Study
Treating patella fractures with a fixed-angle patella plate-A prospective observational study.
Anterior tension wiring using Kirschner wires (K-wires) is still considered the standard treatment for patella fractures, despite its high complication rate. The objective of this prospective clinical study was to evaluate intra- and perioperative complications as well as the clinical outcome of patients with patella fracture treated with a new developed bilateral, polyaxial, fixed-angle 2.7mm patella plate. ⋯ The results of this first clinical study indicate that the fixed-angle patella plate is an effective and safe treatment option for patella fractures with a short operative learning curve. The treatment of communited patella fractures (C3) with a fixed-angle patella plate should be well-considered to avoid distending the indication and biomechanical properties.
-
Despite frequent complaints by orthopaedic trauma patients, to our knowledge there is no data regarding weather's effect on pain and function following acute and chronic fracture. The aim of our study was to investigate the influence of daily weather conditions on patient reported pain and functional status. ⋯ Patient complaints of weather influencing pain after orthopaedic trauma are valid. While pain in the immediate postoperative period is most likely dominated by incisional and soft tissue injuries, as time progresses barometric pressure, temperature, and humidity impact patient pain levels. Affirming and counseling that pain may vary based on changing weather conditions can help manage patient expectations and improve satisfaction.
-
We sought to compare the incidence of complications after fixation of displaced femoral neck fractures in young adults treated with fixed-angle devices versus multiple cancellous screws and a trochanteric lag screw (Pauwel screw). ⋯ In young patients with displaced high-energy femoral neck fractures, fixed-angle devices resulted in fewer treatment failures than did Pauwel screws.
-
To evaluate the influence of joint aspiration on the sensitivity of physical examination for diagnosing acute anterior cruciate ligament (ACL) lesion in the second outpatient-department (OPD) follow-up referred from emergency department (ED). ⋯ Retrospective cohort study III.