Anesthesiology
-
Recent studies suggest that epidural anesthesia initiated before hemorrhage may improve survival and acid-base status in laboratory animals. However, studies of hemorrhagic shock in nonpregnant animals may not be applicable to less severe hemorrhage in pregnant animals. The purpose of this study was to determine whether epidural anesthesia alters maternal and fetal hemodynamic and acid-base responses to hemorrhage in gravid ewes. ⋯ At 45 min (i.e., 30 min after the epidural injection of bupivacaine), epidural bupivacaine resulted in a median sensory level of T9 in the epidural group. At that time, maternal mean arterial pressure was less (P less than 0.05) in the epidural group than in the control group (14 +/- 2% below baseline versus 4 +/- 1% above baseline, respectively). Maternal mean arterial pressure, heart rate, cardiac output, and uterine blood flow, and fetal PO2 and pH all were significantly less during hemorrhage (P less than 0.05) in the epidural group than in the control group.(ABSTRACT TRUNCATED AT 250 WORDS)
-
The authors tested the extent to which thermoregulatory vasoconstriction decreases cutaneous heat loss during isoflurane anesthesia. Thermoregulatory vasoconstriction was provoked by central hypothermia in five nonsurgical volunteers given isoflurane anesthesia. Peripheral arteriovenous shunt flow was quantified using forearm-fingertip skin-surface temperature gradients and volume plethysmography. ⋯ Heat loss from the trunk and head decreased only 14%; in contrast, loss from the hands and feet decreased approximately 57%. There were no clinically important changes in blood pressure or heart rate during vasoconstriction, but oxyhemoglobin saturation (measured by pulse oximetry) increased slightly. These data suggest that thermoregulatory vasoconstriction only minimally decreases cutaneous heat loss.
-
Comparative Study
The effect of desflurane and isoflurane on cerebrospinal fluid pressure in humans with supratentorial mass lesions.
Desflurane, a new volatile anesthetic, produces cerebral vasodilation. The purpose of this study was to compare the effects of 1 MAC desflurane with those of isoflurane on cerebrospinal fluid pressure (CSFP) in patients with supratentorial mass lesions and a mass effect on computerized tomography (CT scan). Twenty adult patients undergoing craniotomy for removal of supratentorial mass lesions were studied. ⋯ Mean arterial pressure was kept within 20% of the patient's mean ward values with the use of esmolol or phenylephrine. CSFP, mean arterial pressure, end-tidal CO2 concentration (PETCO2), hemoglobin O2 saturation, and cerebral perfusion pressure were recorded with the patient awake, immediately postinduction with thiopental, postintubation, after institution of the volatile anesthetic, and every 5 min until the dura was incised. There was no difference in the mean (+/- SD) awake CSFP between the desflurane (11 +/- 4 mmHg) and the isoflurane (10 +/- 2 mmHg) groups.(ABSTRACT TRUNCATED AT 250 WORDS)
-
Comparative Study
Spinal cord stimulation evoked potentials during thoracoabdominal aortic aneurysm surgery.
Although monitoring of somatosensory evoked potentials elicited from stimulation of lower extremity peripheral nerves has been suggested as a method for assessing neural function during thoracoabdominal aortic aneurysm surgery, this technique has been reported to yield a large number of false positives. It was believed that direct stimulation of the spinal cord would eliminate some of the problems associated with peripheral evoked potentials. The present study compared in 18 patients the use of scalp recorded evoked potential following stimulation of either the posterior tibial nerve via percutaneous needles or the spinal cord via an epidural electrode previously placed fluoroscopically. ⋯ Loss of spinal cord stimulation evoked potentials was found to be correlated with adverse neurologic outcome. Over the period of aortic clamping a gradual decrease in mean amplitude (50% at 45 min [P less than 0.05]) and a 20% increase in mean latency time were observed. Maintenance of adequate distal perfusion may permit the use of peripheral evoked potentials in the assessment of spinal cord ischemia during aortic cross-clamping.(ABSTRACT TRUNCATED AT 250 WORDS)