Anesthesiology
-
Randomized Controlled Trial Multicenter Study Clinical Trial
Parecoxib sodium, a parenteral cyclooxygenase 2 selective inhibitor, improves morphine analgesia and is opioid-sparing following total hip arthroplasty.
This study examined the opioid-sparing effectiveness, analgesic efficacy, and tolerability of postoperative administration of the parenteral cyclooxygenase 2 selective inhibitor, parecoxib sodium, in total hip arthroplasty patients. ⋯ Administration of parecoxib sodium with PCA morphine resulted in significantly improved postoperative analgesic management as defined by reduction in opioid requirement, lower pain scores, reduced time on PCA morphine, and higher Global Evaluation ratings.
-
Randomized Controlled Trial Clinical Trial
Simultaneous assessment of drug interactions with low- and high-extraction opioids: application to parecoxib effects on the pharmacokinetics and pharmacodynamics of fentanyl and alfentanil.
Parecoxib is a parenteral cyclooxygenase-2 (COX-2) inhibitor intended for perioperative analgesia. It is an inactive prodrug hydrolyzed in vivo to the active inhibitor valdecoxib, a substrate for hepatic cytochrome P450 3A4 (CYP3A4); hence, a potential exists for metabolic interactions with other CYP3A substrates. This study determined the effects of parecoxib on the pharmacokinetics and pharmacodynamics of the CYP3A substrates fentanyl and alfentanil compared with the CYP3A inhibitor troleandomycin. Alfentanil is a low-extraction drug with a clearance that is highly susceptible to drug interactions; fentanyl is a high-extraction drug and, thus, is theoretically less vulnerable. We therefore also tested the hypothesis that the extraction ratio influences the consequence of altered hepatic metabolism of these opioids. ⋯ Single-dose parecoxib does not alter fentanyl or alfentanil disposition or clinical effects and does not appear to cause significant CYP3A drug interactions. CYP3A inhibition decreases alfentanil clearance more than fentanyl clearance, confirming that the extraction ratio influences the consequence of altered hepatic drug metabolism. Modified cassette, or "cocktail," dosing is useful for assessing drug interactions in humans.
-
Randomized Controlled Trial Clinical Trial
Impact of bispectral index monitoring on fast tracking of gynecologic patients undergoing laparoscopic surgery.
The need for increasing operating room efficiency has led to various initiatives, one of which is the elimination of mandatory admission to the phase I recovery area postoperatively, also referred to as fast tracking of ambulatory surgery patients. This Institutional Review Board-approved study was conducted to evaluate the effect of Bispectral Index (BIS) monitoring on the ability of patients to successfully bypass the phase I recovery area following gynecologic laparoscopy during general anesthesia. ⋯ With a standardized anesthetic regimen and a strict discharge scoring system, BIS monitoring does not have a significant effect on the ability to fast track outpatients.
-
Comparative Study Clinical Trial
Local anesthetic requirements are greater in dystocia than in normal labor.
Dystocia is characterized by abnormal progress of labor and is a common contemporary indication for cesarean delivery in the United States. There has been considerable controversy as to whether epidural analgesia causes dysfunctional labor leading to cesarean delivery for dystocia. The minimum local analgesic concentration (MLAC) is a clinical model used to determine the relative potencies of local anesthetics in the first stage of labor. In this article, the authors report a prospective study determining the MLAC of bupivacaine in early labor of parturients who eventually delivered either vaginally or via cesarean section. ⋯ These data suggest that an increased local anesthetic requirement for epidural labor analgesia is associated with more intense pain related to dystocia. Women in early, clinically normal labor but who later develop dystocia require more local anesthetic and, by inference, are experiencing more severe pain than women who deliver vaginally. This association should be considered when studying the relation between the method of labor analgesia and the course of labor.